Key Features
-
DDR4 test coverage as described by JESD79-4D
-
Test speeds up to 3200 MT/s
-
Perform automated compliance of JEDEC electrical requirements
-
Measurement repeatability, consistency and accuracy
-
Save Pass/Fail reports with annotated screenshots
-
Analyze compliance failures in a dedicated Debug Toolkit
Clock Tests
The DDR4 specification requires clock jitter to be separated into random and deterministic components, which is
a first for DDR specifications. QPHY-DDR4 leverages industry leading serial data algorithms to perform the
jitter breakdown for tJIT(per). In addition to these tests, QPHY-DDR4 will test average clock period, absolute
clock period, average high/low pulse width, absolute high/low pulse width, cycle-cycle jitter, duty cycle
jitter, and cumulative error over n period tests.
Eye Diagram Tests
Eye Diagram tests perform measurements on Data (DQ) and DQS (Strobe) eye diagrams of Read/Write bursts. Tests
measure the horizontal and vertical margin between the JEDEC-specified Rx mask and eye diagram for Write bursts,
and return measurements for Read bursts. Measurements are also performed between the Rx mask and Command Address
signal.
Electrical Tests
The differential and single-ended slew rates defined by the JEDEC standards for DDR4 measure every rising and
falling edge within a write burst. QPHY-DDR4 will measure every transition within each write burst in the
acquisition providing large statistically results in a short period of time. In this picture over 3,000 slew
rate measurements were performed which ensures that the true maximum and minimum points have been caught without
requiring multiple acquisitions.
Timing Tests
DDR4 Timing tests measure timing relationships between data, strobe, and clock signals during both read and
write bursts. Preamble/postamble times and minimum pulse width are also tested.
QualiPHY 2
Automated DDR compliance testing enables faster test times by reducing inconsistencies, testing to the JEDEC
standard and quick stopping for root-causing failures through the DDR Debug Toolkit.
-
Guides the user through each test setup
-
Performs each measurement in accordance with the relevant test procedure
-
Compares each measured value with the applicable specification limits
-
Fully documents all results in a saved PDF with measurement annotations
-
QualiPHY 2 helps the user perform testing the right way—every time!