CP030-3M
30 A, 10 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 3 meter cable
Current Probes CP030B - 30A, 50 MHz High Sensitivity Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable | CP030 - 30A, 50 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable Limited Availability | CP030-3M - 30 A, 10 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 3 meter cable | CP030A - 30A, 50 MHz High Sensitivity Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable Limited Availability | CP031 - 30A, 100 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable | CP031A - 30A, 100 MHz High Sensitivity Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable | CP150B - 150 A, 10 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 2 meter cable | CP150 - 150 A, 10 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 2 meter cable Limited Availability | CP150-6M - 150 A, 5 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 6 meter cable | CP500 - 500 A, 2 MHz Current Probe - AC/DC, 500 A rms, 700 A Peak Pulse, 6 meter cable | CA10 - Programmable Current Sensor to ProBus Adapter for use with third party current sensors | DCS025 - Deskew Calibration Source for Teledyne LeCroy current probes |
Current Probes
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
CP030B - 30A, 50MHz Current Probe
-
CP030-3M - 30 A, 10 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 3 meter cable
-
CP031 - 30A, 100MHz Current Probe
-
CP150B - 150 A, 10 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse
-
CP150-6M - 150 A, 5 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 6 meter cable
-
CP500 - 500 A, 2 MHz Current Probe - AC/DC, 500 A rms, 700 A Peak Pulse
-
DCS025 - Deskew Calibration Source for Teledyne LeCroy current probes
Current Sensor Adapter
The CA10 is a programmable and customizable interface device that seamlessly incorporates third party current transducers/transformers with Teledyne LeCroy oscilloscopes or motor drive analyzers. The easy to use interface provides the ability for the CA10 to be programmed to contain the specifications of the current sensor allowing it to automatically correct for the gain or attenuation and display results in Ampere units. This allows the third party device to be recognized and operate as if it were a Teledyne LeCroy probe.
-
CA10 - Programmable ProBus Current Sensor Adapter for use with third party current sensors
Electrical Characteristics | Bandwidth (Probe Only) | 10 MHz | Coupling | AC 1 MΩ, DC 1MΩ, GND | Risetime (typical) | 35 ns | Max Continuous Input Current | 30 A | Max Peak Current (non-continous) | 50 A | Minimum Sensitivity | 10 mA/div | Amplitude Accuracy | ±1% of reading to 30 A ±2% of reading to 50 A | Maximum Circuit Voltage | 300 V, CAT I (Insulated Wire) | | Environmental and Safety | Operating Temperature | 0 °C to 40 °C | Humidity | ≤ 80 % relative humidity (non-condensing) | Storage Temperature | -10 °C to 50 °C | Max Altitude | 2000 m | | Physical Dimensions | Probe Head Dimensions (L x W x H) | 175 mm x 18 mm x 40 mm | Cable Length | 3 m | Maximum Conductor Size | 5 mm | Weight | 290 g | | General Characteristics | Interface | ProBus | |
|