CP150
150 Amps, 10 MHz BW Current Probe - AC/DC , 500 Amp Peak Pulse
Current Probes CP030B - 30A, 50 MHz High Sensitivity Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable | CP030 - 30A, 50 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable Limited Availability | CP030-3M - 30 A, 10 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 3 meter cable | CP030A - 30A, 50 MHz High Sensitivity Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable Limited Availability | CP031 - 30A, 100 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable | CP031A - 30A, 100 MHz High Sensitivity Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable | CP150B - 150 A, 10 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 2 meter cable | CP150 - 150 A, 10 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 2 meter cable Limited Availability | CP150-6M - 150 A, 5 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 6 meter cable | CP500 - 500 A, 2 MHz Current Probe - AC/DC, 500 A rms, 700 A Peak Pulse, 6 meter cable | CA10 - Programmable Current Sensor to ProBus Adapter for use with third party current sensors | DCS025 - Deskew Calibration Source for Teledyne LeCroy current probes |
Current Probes
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
CP030B - 30A, 50MHz Current Probe
-
CP030-3M - 30 A, 10 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 3 meter cable
-
CP031 - 30A, 100MHz Current Probe
-
CP150B - 150 A, 10 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse
-
CP150-6M - 150 A, 5 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 6 meter cable
-
CP500 - 500 A, 2 MHz Current Probe - AC/DC, 500 A rms, 700 A Peak Pulse
-
DCS025 - Deskew Calibration Source for Teledyne LeCroy current probes
Current Sensor Adapter
The CA10 is a programmable and customizable interface device that seamlessly incorporates third party current transducers/transformers with Teledyne LeCroy oscilloscopes or motor drive analyzers. The easy to use interface provides the ability for the CA10 to be programmed to contain the specifications of the current sensor allowing it to automatically correct for the gain or attenuation and display results in Ampere units. This allows the third party device to be recognized and operate as if it were a Teledyne LeCroy probe.
-
CA10 - Programmable ProBus Current Sensor Adapter for use with third party current sensors
Wide Range of Applications Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies. High Sensitivity The CP030A and CP031A provide a high sensitivity of 1mA/div. This allows for more precise low current measurements on Teledyne LeCroy oscilloscopes. When used with HDO high definition oscilloscopes with HD4096 technology, users will obtain highly accurate, low current waveforms with unmatched 12-bit resolution for improved debug and analysis. Fully Integrated All Teledyne LeCroy current probes are powered through the Teledyne LeCroy ProBus connection and require no additional hardware. Along with providing power, the ProBus connection allows the current probe and oscilloscope to communicate, resulting in current waveforms automatically displayed on screen in Amps, and calculated power traces scaled correctly in Watts. This full integration also allows for the Degauss and Autozero functions to be done directly from the oscilloscope’s user interface. Deskew Calibration Source The DSC015 deskew calibration source has both voltage and current time-aligned signals, which enables the precise deskew of voltage and current probes. Most voltage probes along with the CP030, CP030A, CP031, and CP031A are compatible with the DSC015. Model | Max Continuous Input Current | Max Peak Current | Bandwidth | Minimum Sensitivity | Coupling | Max Conductor Size (diameter) | Interface | CP030 | 30A | 50A | 50 MHZ | 10mA/div | AC, DC, GND | 5mm | Probus, 1MΩ only | CP030A | 30A | 50A | 50 MHZ | 1mA/div | AC, DC, GND | 5mm | Probus, 1MΩ only | CP031 | 30A | 50A | 100 MHZ | 10mA/div | AC, DC, GND | 5mm | Probus, 1MΩ only | CP031A | 30A | 50A | 100 MHZ | 1mA/div | AC, DC, GND | 5mm | Probus, 1MΩ only | AP015 | 30A | 50 A | 50 MHz | 10 mA/div | AC, DC, GND | 5 mm | Probus, 1MΩ only | CP150 | 150 A | 500 A | 10 MHz | 100 mA/div | AC, DC, GND | 20 mm | Probus, 1MΩ only | CP500 | 500 A | 700 A | 2 MHz | 100 mA/div | AC, DC, GND | 20 mm | Probus, 1MΩ only
|
Electrical Characteristics | Bandwidth (Probe Only) | 10 MHz | Coupling | AC 1 MΩ, DC 1MΩ, GND | Risetime (typical) | 35 ns | Max Continuous Input Current | 150 A | Max Peak Current (non-continous) | 300 A | Minimum Sensitivity | 100 mA/div | Amplitude Accuracy | ±1.0 % of reading ±100 mA to 150A ±2.0% of reading to 300A | Maximum Circuit Voltage | 600 V CAT II 300 V CAT III (insulated conductor) | | Environmental and Safety | Operating Temperature | 0 °C to 40 °C | Humidity | ≤ 80 % relative humidity (non-condensing) | Storage Temperature | -10 °C to 50 °C | Max Altitude | 2000 m | | Physical Dimensions | Probe Head Dimensions (L x W x H) | 175 mm x 27 mm x 69 mm | Cable Length | 2 m | Maximum Conductor Size | 20 mm | Weight | 500 g | | General Characteristics | Interface | ProBus | |
|