LabMaster 10 Zi-A 20 GHz Systems   (20 GHz Bandwidth, 4 Input Channels, 80 GS/s Max Sample Rate)
Quick Specs
Sample Rate80 GS/s
Maximum Acquisition Memory512 Mpts/Ch
Input ChannelsUp to 80 @ 20 GHz
Vertical Resolution8-bits
LabMaster 10 Zi-A 25 GHz Systems   (25 GHz Bandwidth, 4 Input Channels, 80 GS/s Max Sample Rate)
Quick Specs
Sample Rate80 GS/s
Maximum Acquisition Memory512 Mpts/Ch
Input ChannelsUp to 80 @ 25 GHz
Vertical Resolution8-bits
LabMaster 10 Zi-A 30 GHz Systems   (30 GHz Bandwidth, 4 Input Channels, 80 GS/s Max Sample Rate)
Quick Specs
Sample Rate80 GS/s
Maximum Acquisition Memory512 Mpts/Ch
Input ChannelsUp to 80 @ 30 GHz
Vertical Resolution8-bits
LabMaster 10 Zi-A 36 GHz Systems   (36 GHz Bandwidth, 4 Input Channels, 80 GS/s Max Sample Rate)
Quick Specs
Sample Rate80 GS/s
Maximum Acquisition Memory512 Mpts/Ch
Input ChannelsUp to 80 @ 36 GHz
Vertical Resolution8-bits
LabMaster 10 Zi-A 50 GHz Systems   (50 GHz Bandwidth, 4 Input Channels, 160 GS/s Max Sample Rate)
Limited Availability
Quick Specs
Sample Rate80 GS/s on 4 Ch
160 GS/s on 2 Ch
Maximum Acquisition Memory1024 Mpts/Ch (2 Ch operation)
Input ChannelsUp to 40 @ 50 GHz,
Up to 80 @ 36 GHz
Vertical Resolution8-bits
LabMaster 10 Zi-A 59 GHz Systems   (59 GHz Bandwidth, 4 Input Channels, 160 GS/s Max Sample Rate)
Limited Availability
Quick Specs
Sample Rate80 GS/s on 4 Ch
160 GS/s on 2 Ch
Maximum Acquisition Memory1024 Mpts/Ch (2 Ch operation)
Input ChannelsUp to 40 @ 60 GHz,
Up to 80 @ 36 GHz
Vertical Resolution8-bits
LabMaster 10 Zi-A 65 GHz Systems   (65 GHz Bandwidth, 4 Input Channels, 160 GS/s Max Sample Rate)
Limited Availability
Quick Specs
Sample Rate80 GS/s on 4 Ch
160 GS/s on 2 Ch
Maximum Acquisition Memory1024 Mpts/Ch (2 Ch operation)
Input ChannelsUp to 40 @ 65 GHz,
Up to 80 @ 36 GHz
Vertical Resolution8-bits
Check up to three models.
The Ultimate in High Bandwidth Performance
  • Up to 65 GHz
  • Up to 80 Channels @ 36 GHz
  • Up to 160 GS/s
  • Up to 512 Mpts/Ch
  • 50 fs rms Sample Clock (Intrinsic) Jitter
  • Jitter Between All Channels of <130 fs rms
LabMaster 10 Zi modular systems re-define oscilloscope performance and capabilities.
  • Multi-channel operation at the highest bandwidths
    • 40 channels @ 65, 60 or 50 GHz
    • 80 channels @ 36, 30, or 25 GHz
  • Bandwidth and channel upgrade flexibility
  • ChannelSync for precise synchronization of all acquisition modules
    • <130 fs rms Jitter Between All Channels
  • Server-class CPU w/ 32 GB RAM standard
  • Ultra-high stability sample clock, Jitter <50 fs rms
  • 4.9 ps (20-80%) rise time
  • 14.1 Gb/s hardware serial trigger

 

Vertical - Analog Channels

Analog Bandwidth (Max) 30 GHz
Bandwidth 30 GHz
Analog Bandwidth @ 50 Ω (-3 dB) (ProAxial/2.92mm Inputs) 30 GHz
(≥5 mV/div)
Rise Time (10-90%, 50 Ω) 12.8 ps
(test limit, flatness mode)
Rise Time (20-80%, 50 Ω) 9.6 ps
(flatness mode)
Input Channels Up to 80, depending on configuration selected.
(Any combination of up to 80 2.92mm input channels)
Vertical Resolution 8 bits; up to 11 bits with enhanced resolution (ERES)
Sensitivity 50 Ω (2.92mm): 5 mV-500mV/div, fully variable (5-9.9 mV/div via zoom)
DC Vertical Gain Accuracy (Gain Component of DC Accuracy) ±1% F.S. (typical), offset at 0V; ±1.5% F.S. (test limit), offset at 0V
Channel-Channel Isolation DC to 36 GHz: 60 dB (>1000:1)
(For any two 2.92mm input channels, same or different v/div settings, typical)
Offset Range 50 Ω:
±500 mV @ 5-75 mV/div
±4 V @ 76 mV/div -500mV/div
DC Vertical Offset Accuracy ±(1.5% of offset setting + 1.5% F.S. + 1 mV) (test limit)
Maximum Input Voltage 2.92 mm Inputs: ±2 Vmax@<76mV/div, 5.5Vrms@≥76mV/div
Input Coupling 2.92 mm Inputs: 50 Ω: DC, GND
Input Impedance 2.92mm Inputs: 50 Ω+/-2%
Bandwidth Limiters 1, 3, 4, 6, 8, 13, 16, 20, 25 GHz
Rescaling Length: meters, inches, feet, yards, miles; Mass: grams, slugs; Temperature: celsius, fahrenheit, kelvin; Angle: radian, arcdegr, arcmin, arcsec, cycles, revolutions, turns; Velocity: m/s, in/s, ft/s, yd/s, miles/s; Acceleration: m/s2, in/s2, ft/s2, g0; Volume: liters, cubic meters, cubic inches, cubic feet, cubic yards; Force (Weight): newton, grain, ounce, pound; Pressure: pascal, bar, atmosphere (technical), atmosphere (standard), torr, psi; Electrical: volts, amps, watts, volt-amperes, volt-amperes reactive, farad, coulomb, ohm, siemen, volt/meter, coulomb/m2, farad/meter, siemen/meter, power factor; Magnetic: weber, tesla, henry, amp/meter, henry/meter; Energy: joule, Btu, calorie; Rotating Machine: radian/second, frequency, revolution/second, revolution/minute, N m, lb-ft, lb-in, oz-in, watt, horsepower; Other: %.
 

Horizontal - Analog Channels

Timebases Internal timebase with 10 GHz clock frequency common to all input channels. Single, distributed 10 GHz clock for all channels ensures precise synchronization with timing accuracy between all channels identical to that provided within a single, conventional oscilloscope package.
Time/Division Range 10 ps/div-256 s/div (maximum capture time is based on minimum sample rate of 200kS/s and installed memory).
Clock Accuracy <0.1 ppm + (aging of 0.05 ppm/yr from last calibration)
Sample Clock Jitter up to 3.2ms Acquired Time Range:
50fsrms (Internal Timebase Reference)
50fsrms (External Timebase Reference)
up to 6.4ms Acquired Time Range:
130fsrms (Internal Timebase Reference)
130fsrms (External Timebase Reference)
Delta Time Measurement Accuracy \sqrt{2}*\sqrt{(\frac{Noise}{SlewRate})^2+(Sample Clock Jitter)^2) (RMS)+(clock accuracy*reading)(seconds)
Jitter Measurement Floor \sqrt{(\frac{Noise}{SlewRate})^2+(Sample Clock Jitter)^2\; seconds\; rms\; (TIE)}
Jitter Between Channels <250fsrms
(TIE, typical, measured at maximum bandwidth)
Channel-Channel Deskew Range ±9 x time/div. setting or 25 ns max. (whichever is larger), each channel
External Timebase Reference (Input) 10 MHz or 100MHz; 50 Ω impedance, applied at the rear input of MCM-Zi-A Master Control Module
External Timebase Reference (Output) 10 MHz or 100 MHz ; 50 Ω impedance, output at the rear of MCM-Zi-A Master Control Module
 

Acquisition - Analog Channels

Sample Rate (Single-shot) 80 GS/s on each channel.
Memory Length (4 Ch / 2 Ch / 1Ch)
(Number of Segments)
32 M / 32 M / 32M
(1000)
Memory Length Options (4 Ch / 2 Ch / 1Ch)
(Number of Segments)
S-32 Option:
32M / 32M / 32M
(7,500)
M-64 Option:
64M / 64M / 64M
(15,000)
L-128 Option:
128M / 128M / 128M
(15,000)
VL-256 Option:
256M / 256M / 256M
(15,000)
XL-512 Option:
512M / 512M / 512M
(15,000)
Intersegment Time 1 µs
Averaging Summed averaging to 1 million sweeps; continuous averaging to 1 million sweeps
Enhanced Resolution (ERES) From 8.5 to 11 bits vertical resolution
Envelope (Extrema) Envelope, floor, or roof for up to 1 million sweeps
Interpolation Linear or Sin x/x
 

Triggering System

Max Trigger Frequency (C1-C4, Aux In, SMART Trigger) For Ch 1-4 only of any LabMaster 10xx-Zi-A Acquisition Module:
2.0 GHz @ ≥ 10 mV/div (minimum triggerable width 200 ps)
Modes Normal, Auto, Single, and Stop
Sources Any Ch 1-4 (Edge, Window, SMART, Cascade triggers), AUX, internal Fast Edge; or any input channel (Edge trigger only) on additional 10-xxZi-A Acquisition Modules (Channels 5 and higher).
Slope and level unique to each source except line trigger.
Coupling DC, AC, HFRej, LFRej
Pre-trigger Delay 0-100% of memory size (adjustable in 1% increments of 100 ns)
Post-trigger Delay 0-10,000 divisions in real time mode, limited at slower time/div settings
Hold-off From 2 ns up to 20 s or from 1 to 99,999,999 events
Trigger and Interpolator Jitter <0.1 ps rms (typical, software assisted), 2 ps rms (typical, hardware),
Internal Trigger Level Range ±4.1 div from center
External Trigger Level Range For any LabMaster 10xx-Zi-A Acquisition Module: Aux (±0.4 V)
(Only Ch1-4 Acquisition Module has active AUX Input)
Maximum Trigger Rate 1,000,000 waveforms/second (in Sequence Mode, up to 4 channels)
Trigger Sensitivity with Edge Trigger (1.85/2.4/2.92mm Inputs) For Ch 1-80 of a LabMaster 10 Zi-A system:
3 div @ < 12 GHz
1.5 div @ < 3 GHz
1.0 div @ < 200 MHz
(for DC coupling, ≥ 10 mV/div, 50 Ω )
Trigger Sensitivity with Edge Trigger (Aux Input) For Ch 1-4 only of any LabMaster 10xx-Zi-A Acquisition Module:
2 div @ < 1 GHz,
1.5 div @ < 500 MHz,
1.0 div @ < 200 MHz,
(for DC coupling)
 

Trigger Types

Edge Triggers when signal meets slope (positive, negative, or either) and level condition.
Width Triggers on positive, negative, or both widths with widths selectable as low as 200ps to 20 s, or on intermittent faults.
Glitch Triggers on positive or negative glitches with widths selectable as low as 200ps to 20 s, or on intermittent faults.
Window Triggers when signal exits a window defined by adjustable thresholds
Pattern Logic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input). Each source can be high, low, or don’t care. The High and Low level can be selected independently. Triggers at start or end of the pattern.
Runt Trigger on positive or negative runts defined by two voltage limits and two time limits. Select between 1 ns and 20 ns.
Slew Rate Trigger on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 ns.
Interval Triggers on intervals selectable between 1 ns and 20 s.
Dropout Triggers if signal drops out for longer than selected time between 1 ns and 20 s.
Measurement Trigger Select from a large number of measurement parameters trigger on a measurement value with qualified limits. Can be used as only trigger or last event in a Cascade Trigger.
Multi-Stage: Qualified (Timeout or State/Edge Qualified) Triggers on any input source only if a defined state or edge occurred on another input source. Holdoff between sources is selectable by time or events.
Triggers with Exclusion Technology Trigger on intermittent faults by specifying the expected behavior and triggering when that condition is not met
Multi-Stage: Qualified First In Sequence acquisition mode, triggers repeatably on event B only if a defined pattern, state, or edge (event A) is satisfied in the first segment of the acquisition. Holdoff between sources is selectable by time or events.
Multi-Stage: Cascade (Sequence) Trigger, Capability Arm on A event, then Trigger on B event. Or Arm on A event, then Qualify on B event, and Trigger on C event.
Multi-Stage: Cascade (Sequence) Trigger, Types Cascade A then B: Edge, Window, Pattern (Logic) Width, Glitch, Interval, Dropout, or Measurement. Measurement can be on Stage B only.
Cascade A then B then C (Measurement): Edge, Window, Pattern (Logic), Width, Glitch, Interval, Dropout, or Measurement. Measurement can be on Stage C only.
Cascade A then B then C: Edge, Window, Pattern (Logic)
Multi-Stage: Cascade (Sequence) Trigger, Holdoff Holdoff between A and B or B and C is selectable by time or number of events.
Measurement trigger selection as the last stage in a Cascade precludes a holdoff setting between the prior stage and the last stage.
 

High Speed Serial Protocol Trigger

Data Rates Option LM10Zi-6GBIT-80B-SYMBOL-TD: 600 Mb/s to 6.5 Gb/s, Channel 4 input only
Option LM10Zi-14GBIT-80B-SYMBOL-TD: 600 Mb/s to 14.1 Gb/s, Channel 4 input only
Pattern Length 80 bits NRZ, eight 8b/10b symbols, 64b/66b symbol
 

Display System

Size On LabMaster MCM-Zi Master Control Module: Color 15.3 flat panel TFT-Active Matrix LCD with high resolution touch screen
Resolution WXGA; 1280 x 768 pixels.
Number of traces Display a maximum of 40 traces. Simultaneously display channel, zoom, memory and math traces.
Grid Styles Auto, Single, Dual, Triple, Quad, Octal, X-Y, Single+X-Y, Dual+X-Y, Twelve, Sixteen. Up to twenty grids available with some software options.
Waveform Representation Sample dots joined, or sample dots only
 

Integrated Second Display

Size Supports touch screen integration of user-supplied second display with split-grid capability.
(Note: touch screen driver for second display may not be a Fujitsu driver)
Resolution Determined by display chosen by user
 

LeCroy WaveStream™ Fast Viewing Mode

Intensity 256 Intensity Levels, 1-100% adjustable via front panel control
Types Select analog or color-graded
Number of Channels up to 80 simultaneously
Max Sampling Rate 80GS/s
Persistence Aging Select from 500 ms to Infinity
Waveforms/second (continuous) up to 2500 Waveforms/second
Operation Front panel toggle between WaveStream ON (Analog), ON (Color) and OFF
 

Persistence Display

Analog and Color-Graded Persistence Variable saturation levels; stores each trace’s persistence data in memory
Persistence Types Select analog, color, or three-dimensional
Trace Selection Activate persistence on all or any combination of traces
Persistence Aging Select from 500 ms to infinity
Sweep Display Modes All accumulated, or all accumulated with last trace highlighted
 

High Speed Digitizer Output (Option)

Type Option LSIB-2. Installs in LabMaster MCM-Zi Master Control Module and uses one available PCIe slot normally used by a LabMaster 10-xxZi Acquisition Module.
Transfer Rate up to 325 MB/s (typical) - Maximum of 4 channels (consult Teledyne LeCroy for >4 channels)
Output Protocol PCI Express, Gen 1 (4 lanes utilized for data transfer)
Control Protocol TCP/IP
Command Set Via Windows Automation, or via LeCroy Remote Command Set
 

Zoom Expansion Traces

Zoom Expansion Traces Display up to 12 Zoom and 12 Math/Zoom traces
 

Internal Waveform Memory

Internal Waveform Memory 12 active waveform memory traces (M1-M12) store 16 bit/point full length waveforms. Waveforms can be stored to any number of files limited only by the data storage media capacity.
 

Setup Storage

Front Panel and Instrument Status Store to the internal hard drive, over the network, or to a USB-connected peripheral device.
 

Automatic Setup

Auto Setup Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals
Find Vertical Scale Automatically sets the vertical sensitivity and offset for the selected channel to display a waveform with the maximum dynamic range
 

Calibration

Auto Calibration Ensures specified DC and timing accuracy is maintained for 1 year minimum.
 

Processor/CPU

Processor Memory 32 GB standard. Up to 192 GB optionally available.
Operating System Microsoft Windows® 10
Oscilloscope Operating Software Teledyne LeCroy MAUI™ with OneTouch
Real Time Clock Date and time displayed with waveform in hardcopy files. SNTP support to synchronize to precision internal clocks.
 

Connectivity

Ethernet Port Supports 10/100/1000BaseT Ethernet interface (RJ45 port)
USB Host Ports LabMaster MCM-Zi -A Master Control Module: minimum 2 total USB 2.0 ports on rear of unit to support Windows compatible devices
LabMaster MCM-Zi -A Master Control Module: minimum 3 total USB 2.0 ports on front of unit to support Windows compatible devices
GPIB Port (optional) Supports IEEE - 488.2. Installs in LabMaster MCM-Zi Master Control Module and uses one available PCIe slot normally used by a LabMaster 10-xxZi Acquisition Module.
External Monitor Port Dual Link DVI compatible to support internal display on MCM-Zi Master Control Module (1280 x 768 pixel resolution) and customer-supplied monitor with up to WQXGA (2560 x 1600 pixel) resolution using extended desktop mode.
Remote Control Via Windows Automation, or via LeCroy Remote Command Set
Network Communication Standard VXI-11 or VICP, LXI Class C (v1.2) Compliant
LSIB Port (optional) Supports PCIe Gen1 x4 protocol with LeCroy supplied API. Installs in LabMaster LabMaster MCM-Zi-A Master Control Module and uses one available PCIe slot normally used by a LabMaster 10-xxZi-A Acquisition Module.
 

Auxiliary Input

Signal Types For External Trigger Input. Located on every LabMaster 10-xxZi-A Acquisition Module (front-mounted BNC, 50 Ω). 10-xxZi-A Acquisition Module that is used for Channels 1-4 contains active AUX Input.
Coupling 50 Ω: DC
Max. Input Voltage 5 Vrms
 

Auxiliary Output

Signal Types Select from calibrator, control signals or Off
Output Signal 500 Hz-5 MHz square wave or DC level; 0.0 to 500 mV into 50 Ω (0-1 V into 1 MΩ)
Control Signals Trigger enabled, trigger out, pass/fail status, off
Connector Type BNC, located on front of every LabMaster 10-xxZi Acquisition Module. 10-xxZi Acquisition Module that is used for Channels 1-4 contains active AUX Output.
 

Probes

Probing System 2.92mm interface automatically detects and supports a variety of compatible probes.
Use L2.92A-PLINK or L2.92A-PBUS 2.92mm Probe Adapters to connect 50Ω ProLink or 50Ω ProBus compatible probes to 2.92mm interface.
Probes No passive probes supplied
Scale Factors Automatically or manually selected depending on probe used
Calibration Output MCM-Zi-A Master Control Module: Fast Edge output, 5MHz square wave, 350mVp-p (typical), 50ps rise time, output to SMA connector, AC Coupled
 

Power Requirements

Voltage LabMaster 10-xxZi Acquisition Module: 100-240 VAC ±10% at 45-66 Hz; 100-120 VAC ±10% at 380-420 Hz; Automatic AC Voltage Selection, Installation Category II
LabMaster MCM-Zi Master Control Module: 100-240 VAC ±10% at 45-66 Hz; Automatic AC Voltage Selection, Installation Category II
Max. Power Consumption LabMaster 10-xxZi-A Acquisition Module - 1225 W / 1225 VA.
LabMaster MCM-Zi-A Master Control Module - 450 W / 450 VA.
Each Module and the CPU has a separate power cord.
 

Environmental

Temperature (Operating) +5 °C to +40 °C
Temperature (Non-Operating) -20 °C to +60 °C
Humidity (Operating) 5% to 80% relative humidity (non-condensing) up to +31 °C.
Upper limit derates to 50% relative humidity (non-condensing) at +40 °C.
Humidity (Non-Operating) 5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F
Altitude (Operating) Up to 10,000 ft. (3048 m) at or below +25 °C
Altitude (Non-Operating) Up to 40,000 ft. (12,192 m)
Random Vibration (Operating) 0.5 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Random Vibration (Non-Operating) 2.4 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Functional Shock 20 g peak, half sine, 11 ms pulse, 3 shocks (positive and negative) in each of three orthogonal axes, 18 shocks total
 

Size and Weight

Dimensions (HWD) LabMaster MCM-Zi-A Master Control Module - 10.9H x 18.2W x 15.6D (277 x 462 x 396 mm),
LabMaster 10-xxZi-A Acquisition Module - 8.0H x 18.2W x 26D (202 x 462 x 660 mm)
Weight LabMaster 10-xxZi-A Acquisition Module -53 lbs. (24.1 kg)
LabMaster MCM-Zi-A Master Control Module - 47 lbs. (21.4 kg),
Shipping Weight LabMaster 10-xxZi-A Acquisition Module -71 lbs. (32.3 kg)
LabMaster MCM-Zi-A Master Control Module - 56 lbs. (25.5 kg)
 

Certifications

CE Certification
UL and cUL Listing
CE Compliant, UL and cUL listed; conforms to EN 61326, EN 61010-1, EN61010-2-030, UL 61010-1 3rd edition, and CSA C22.2 No. 61010-1-12
 

Warranty and Service

Warranty and Service 3-year warranty; calibration recommended annually.
Optional service programs include extended warranty, upgrades, and calibration services.
 

LabMaster Acquisition Modules

LabMaster 10-20Zi-A
20 GHz, 80 GS/s, 4ch, 32 Mpts/Ch LabMaster Acquisition Module, 50 Ohm Input
LabMaster 10-25Zi-A
25 GHz, 80 GS/s, 4ch, 32 Mpts/Ch LabMaster Acquisition Module, 50 Ohm Input
LabMaster 10-30Zi-A
30 GHz, 80 GS/s, 4ch, 32 Mpts/Ch LabMaster Acquisition Module, 50 Ohm Input
LabMaster 10-36Zi-A
36 GHz, 80 GS/s, 4ch, 32 Mpts/Ch LabMaster Slave Acquisition Module, 50 Ohm Input
LabMaster 10-50Zi-A
50 GHz, 160 GS/s, 64 Mpts/Ch Digital Bandwidth Interleaved Acquisition Module, 50 Ohm Input Also operates in 36 GHz, 80 GS/s, 4ch, 32 Mpts/Ch mode. Limited Availability
LabMaster 10-59Zi-A
59 GHz, 160 GS/s, 64 Mpts/Ch Digital Bandwidth Interleaved Acquisition Module, 50 Ohm Input Also operates in 36 GHz, 80 GS/s, 4ch, 32 Mpts/Ch mode. Limited Availability
LabMaster 10-65Zi-A
65 GHz, 160 GS/s, 64 Mpts/Ch Digital Bandwidth Interleaved Acquisition Module, 50 Ohm Input. Also operates in 36 GHz, 80 GS/s, 4ch, 32 Mpts/Ch mode. Limited Availability

Mixed Signal Solutions

HDA125-09-SYNC
12.5 GS/s High-speed Digital Analyzer with 9ch QuickLink leadset and SYNC connection
HDA125-18-SYNC
12.5 GS/s High-speed Digital Analyzer with 18ch QuickLink leadset and SYNC connection

Memory Options

LM10Zi-VL-256
256 Mpt/Ch Memory Option for LabMaster 10 Zi Acquisition Modules
LM10Zi-XL-512
512 Mpt/Ch Memory Option for LabMaster 10 Zi Acquisition Modules
SDA10Zi-L-128
128 Mpt/Ch Memory Option for LabMaster 10 Zi Acquisition Modules used with SDA MCM-Zi
SDA10Zi-XL-512
512 Mpt/Ch Memory Option for LabMaster 10 Zi Acquisition Modules used with SDA MCM-Zi
LM10Zi-M-64
64 Mpt/Ch Memory Option for LabMaster 10 Zi Acquisition Modules
LM10Zi-L-128
128 Mpt/Ch Memory Option for LabMaster 10 Zi Acquisition Modules

Computer Upgrade

MCMZi-500GB-RHD-02
Additional 500 GB Hard Drive for MCM-Zi
MCMZi-32-UPG-128GB
Upgrade from 32 GB to 128 GB CPU RAM at time of initial shipment
MCMZi-32-UPG-192GB
Upgrade from 32 GB to 192 GB CPU RAM at time of initial shipment

Remote Control/Network Options

USB2-GPIB
External USB 2.0 to GPIB IEEE 488.2 adapter
GPIB-3
GPIB Option for LabMaster MCM-Zi

Power Analysis Software

LM10Zi-PWR
Power Analysis Option for LM 10 Zi

Serial Trigger and Decode

LM10ZI-PCIE6BUS D
PCI Express 6.0 to 1.0 Protocol Link Layer Decode Annotation for LabMaster 10 Zi Series
LM10Zi-1553 D
MIL-STD-1553 Decode option for LabMaster 10Zi Series
LM10ZI-USB4BUS DME
USB4 and Thunderbolt Decode, Measure/Graph, and Eye Measurements Option for LabMaster 10 Zi
LM10Zi-64B66B D
64b/66b Decode option for LabMaster 10Zi Series
LM10Zi-6GBIT-80B-SYMBOL-TD
80-bit NRZ, 8b/10b, and 64b/66b 6.5 Gbps Serial Trigger option for LabMaster 10 Zi Limited Availability
LM10Zi-8B10B D
8b/10b Decode option for LabMaster 10Zi Series
LM10ZI-USB4SB DMP
USB4-SB Decode, Measure/Graph, and PHY Measurement Option LabMaster 10 Zi
LM10ZI-USB4SB D
USB4-SB Decode Option LabMaster 10 Zi
LM10Zi-ARINC429bus Dsymbolic
ARINC 429 Symbolic Decode for LabMaster 10Zi Series
LM10Zi-AUDIOBUS D
Audio (I2S) Decode for LabMaster 10 Zi Series
LM10Zi-AUDIOBUS DG
Audio (I2S) Decode and Graphing for LabMaster 10 Zi Series
LM10Zi-CAN FDbus D
CAN and CAN FD Decode Option for LabMaster 10Zi Oscilloscopes
LM10Zi-CPHYBUS D
C-PHY (DSI-2/CSI-2) Decode Option for LabMaster 10 Zi/-A
LM10Zi-CPHYBUS DMP
C-PHY (DSI-2/CSI-2) Decode, Measure/Graph and Physical Layer Option for LabMaster 10 Zi/-A
LM10Zi-DigRF3Gbus D
DigRF 3G Decode for LabMaster 10 Zi Series
LM10Zi-DigRFv4bus D
DigRF v4 Decode for LabMaster 10 Zi Series
LM10ZI-DPAUX D
DisplayPort AUX Decode Option for LabMaster 10 Zi
LM10ZI-DPAUX DMP
DisplayPort AUX Decode, Measure/Graph, and Physical Layer Option LabMaster 10 Zi
LM10Zi-DPHYbus D
MIPI DPHY Decode for LabMaster 10 Zi Series
LM10Zi-DPHYbus DP
MIPI DPHY Decode and Physical Layer Test for LabMaster 10 Zi Series
LM10ZI-ENET10GBUS D
Ethernet 10GBASE-R Decode for LabMaster 10 Zi Series
LM10Zi-ENETbus D
ENET Bus Decode Option for LabMaster 10Zi
LM10Zi-FCbus D
FibreChannel Decode for LabMaster 10 Zi Series
LM10Zi-FLEXRAYBUS D
FlexRay Decode for LabMaster 10 Zi Series
LM10Zi-FLEXRAYBUS DP
FlexRay Decode and Physical Layer Test for LabMaster 10 Zi Series
LM10Zi-I2CBUS D
I2C Decode for LabMaster 10 Zi Series
LM10ZI-I3CBUS D
I3C Decode Option for LabMaster 10 Zi Series
LM10ZI-I3CBUS DME
I3C Decode, Measure/Graph, and Eye Diagram Option for LabMaster 10 Zi Series
LM10Zi-LINBUS D
LIN Decode for LabMaster 10 Zi Series
LM10Zi-Manchesterbus D
Manchester Bus Decode Option for LabMaster 10Zi
LM10Zi-MDIObus D
MDIO Decode for LabMaster 10Zi/Zi-A Series
LM10Zi-MPHYbus D
MIPI MPHY Decode for LabMaster 10 Zi Series
LM10Zi-MPHYbus DP
MIPI MPHY Decode and Physical Layer Test for LabMaster 10 Zi Series
LM10Zi-PCIEBUS D
PCI Express (Gen 1.x, 2.0, 3.0 & 4.0) Protocol Link Layer Decode Annotation - LabMaster 10 Zi Series
LM10Zi-PROTOSYNC
Decode Annotation and Protocol Analyzer Software Synchronization Option for LabMaster 10 Zi Series
LM10Zi-PROTOSYNC-BT
Decode Annotation & Protocol Analyzer+Bit Tracer SW Synchronization Option for LabMaster 10Zi Series
LM10Zi-SASbus D
SAS Decode for LabMaster 10 Zi Series
LM10Zi-SATAbus D
SATA Decode for LabMaster 10 Zi Series
LM10ZI-SENTbus D
SENT Bus Decode Option for LabMaster 10Zi
LM10Zi-SpaceWirebus D
SpaceWire Decode Option for LabMaster 10Zi series
LM10Zi-SPIBUS D
SPI Decode for LabMaster 10 Zi Series
LM10Zi-SPMIbus D
SPMI Decode for LabMaster 10Zi/Zi-A Series
LM10Zi-UART-RS232BUS D
UART-RS232 Decode for LabMaster 10 Zi Series
LM10ZI-UNIPRObus D
MIPI UniPro Protocol Decoder Software Option
LM10Zi-USB2bus D
USB1.1x, 2.0 Decode for LabMaster 10 Zi Series
LM10ZI-USB32BUS D
USB 3.2 Decode for LabMaster 10 Zi Series
LM10ZI-USBPD D
USB-PD Decode Option for LabMaster 10 Zi
LM10ZI-USBPD DMP
USB-PD Decode, Measure/Graph, and Physical Layer Option LabMaster 10 Zi

Jitter Analysis Software

LM10ZI-CLOCK-X
Clock Expert Jitter Analysis Framework
LM10ZI-CLOCK-X-PRO
Clock Expert Jitter Analysis Framework with SSC, Phase Noise and Accumulated Jitter Analysis
LM10Zi-JITKIT
Clock Jitter Analysis Package for LabMaster 10 Zi Series

Digital Filtering Software

LM10Zi-DFP2
Digital Filter Software Package for LabMaster 10 Zi Series

Serial Data Compliance

QPHY2-PC
QualiPHY 2 PC Off-line Compliance Software (Permanent License) Includes Permanent MAUI Studio Pro License
QPHY2-USB4-TX-RX
QualiPHY 2 Enabled USB4 and Thunderbolt Transmitter and Receiver Compliance Software Option
QPHY2-PC-1YR
QualiPHY 2 PC Off-line Compliance Software (1 Year renewable License) Includes 1 Year MAUI Studio Pro License
QPHY2-PCIE6-TX-RX
QualiPHY 2 Enabled PCIe 6.0 through 1.0 Compliance Software Option Includes PCIe Tx/Rx and CXL Tx electrical tests
LM10ZI-AUTO-ENET-TOOLKIT
100Base-T1 and 1000Base-T1 Debug Toolkit for LabMaster 10Zi
LM10ZI-DDR2-TOOLKIT
DDR 2 and LPDDR 2 Debug Toolkit for LabMaster 10Zi Oscilloscopes
LM10ZI-DDR3-TOOLKIT
DDR 3/2 and LPDDR 3/2 Debug Toolkit for LabMaster 10Zi Oscilloscopes
LM10ZI-DDR4-TOOLKIT
DDR2/3/4 and LPDDR2/3/4/4X Debug Toolkit for the LabMaster 10Zi Oscilloscopes
LM10ZI-DDR5-TOOLKIT
DDR 2/3/4/5 and LPDDR 2/3/4/4X Debug Toolkit for LabMaster 10Zi Oscilloscopes
QPHY-10Base-T1L
QualiPHY Enabled 10Base-T1L (Industrial Ethernet) Compliance Software Option
QPHY-10Base-T1S
QualiPHY Enabled 10Base-T1S (Automotive Ethernet) Compliance Software Option
QPHY-10GBase-KR
QualiPHY Enabled 10GBase-KR Compliance Software Option
QPHY-10GBASE-T
QualiPHY Enabled 10GBASE-T Transmitter and Return Loss Compliance Test Software Option
QPHY-56G-PAM4
QualiPHY Enabled 56G PAM4 Compliance Software Option
QPHY-DDR3
QualiPHY Enabled DDR3, DDR3L and LPDDR3 Compliance Software Option
QPHY-DDR4
QualiPHY Enabled DDR4 and LPDDR4 Compliance Software Option
QPHY-DP14-SOURCE
QualiPHY Enabled DisplayPort 1.4 Source Compliance Software Option
QPHY-DP20-SINK
QualiPHY Enabled DisplayPort 2.0 Sink Compliance Software Option
QPHY-DP20-SOURCE
QualiPHY Enabled DisplayPort 2.0 Source Compliance Software Option (Includes QPHY-DP14-SOURCE)
QPHY-eDP
QualiPHY Enabled Embedded DisplayPort Compliance Software Option
QPHY-HDMI2
QualiPHY Enabled HDMI 2.0/1.4b TMDS Compliance Software Option
QPHY-HDMI21
QualiPHY Enabled HDMI 2.1 FRL and TMDS Compliance Software Option
QPHY-MIPI-CPHY
QualiPHY Enabled MIPI C-PHY Compliance Software Option (includes C-PHY DMP)
QPHY-MIPI-MPHY
QualiPHY Enabled MIPI M-PHY Compliance Software Option
QPHY-MultiGBase-T1
QualiPHY Enabled MultiGBase-T1 (Automotive Ethernet) Compliance Software Option
QPHY-PCIe
QualiPHY Enabled PCIe 2.0 and 1.0 Compliance Software Option Includes PCIe Tx/Rx and CXL Tx electrical tests
QPHY-PCIE3-TX-RX
QualiPHY Enabled PCIe 3.0 through 1.0 Compliance Software Option Includes PCIe Tx/Rx and CXL Tx electrical tests
QPHY-PCIE4-TX-RX
QualiPHY Enabled PCIe 4.0 through 1.0 Compliance Software Option Includes PCIe Tx/Rx and CXL Tx electrical tests
QPHY-PCIE5-TX-RX
QualiPHY Enabled PCIe 5.0 through 1.0 Compliance Software Option Includes PCIe Tx/Rx and CXL Tx electrical tests
QPHY-PCIE6-TX-RX
QualiPHY Enabled PCIe 6.0 through 1.0 Compliance Software Option Includes PCIe Tx/Rx and CXL Tx electrical tests
QPHY-SAS2
QualiPHY Enabled SAS2 (1.5 Gb/s, 3.0 Gb/s, and 6.0 Gb/s) Compliance Software Option
QPHY-SAS3
QualiPHY Enabled SAS3 (1.5 Gb/s, 3.0 Gb/s, 6.0 Gb/s, and 12.0 Gb/s) Compliance Software Option
QPHY-SATA-TSG-RSG
QualiPHY Enabled SATA (PHY, TSG, RSG, and OOB) Compliance Software Option
QPHY-SFI
QualiPHY Enabled SFI Compliance Software Option
QPHY-USB3.2-Tx-Rx
QualiPHY Enabled USB 3.2 Compliance Tx-Rx Software Option
QPHY-USB4-TX-RX
QualiPHY Enabled USB4 and Thunderbolt Transmitter and Receiver Compliance Software option

Serial Data Analysis

LM10ZI-SDAX-PCIE6
SDA Expert Technology Framework for PCIe 6
LM10ZI-SDAX-USB4-TBT
SDA Expert Technology Framework for USB4 and Thunderbolt 3
LM10ZI-SDAX-COMPLETE
Bundle - Multi-Lane SDA Expert Framework, incl. Eye, Jitter, Noise, Xtalk Meas and VirtualProbe
LM10ZI-SDAX-PCIE-NRZ
SDA Expert Technology Framework for PCIe NRZ
LM10ZI-SDAX-USB32
SDA Expert Technology Framework for USB3.2
LM10ZI-SDAX-NRZ
NRZ Serial Data Expert Analysis Framework, Eye, Jitter and Noise Measurements
LM10ZI-SDAX-PAM
PAM Serial Data Expert Analysis Framework, Eye,Jitter and Noise Measurements
LM10Zi-VIRTUALPROBE
Advanced De-embedding, Emulation and Virtual Probing Toolkit
LM10Zi-CBL-DE-EMBED
Cable De-embedding Option for LabMaster 10 Zi Series
LM10Zi-EYEDRII
Signal Integrity Toolkit - Channel & Fixture De-embedding/Emulation, Tx/Rx Equalization
LM10Zi-EYEDRII-VP
Bundle - EyeDrII and VirtualProbe Toolkits
LM10Zi-SDM
Serial Data Mask Software Package for LabMaster 10 Zi Series

Other Software Options

LM10ZI-CROSSSYNC-PHY-PCIE
PCIe CrossSync PHY protocol analyzer synchronization for LabMaster 10 Zi
LM10ZI-CROSSSYNC-PHY-USB
USB CrossSync PHY protocol analyzer synchronization for LabMaster 10 Zi
LM10Zi-EMC
EMC Pulse Parameter Software Package for LabMaster 10 Zi Series
LM10ZI-OPTICAL-LINQ
Coherent optical analysis software for LabMaster 10Zi
LM10Zi-SPECTRUM-1
Spectrum Analyzer for LabMaster 10 Zi - 1 trace
LM10Zi-SPECTRUM-PRO-2R
Spectrum Analyzer for LabMaster 10 Zi - 2 traces + reference
LM10Zi-VECTORLINQ
VectorLinQ Vector Signal Analysis
LM10Zi-VECTORLINQ-ADV
VectorLinQ Advanced Vector Signal Analysis incl OFDM
MAUI Studio Pro
MAUI Studio Pro Offline Remote and PC Analysis Software License

Miscellaneous

MCM-Zi-RACKMOUNT
Rackmount for MCM-Zi
LM10Zi-ACQMOD-RACKMOUNT
Rackmount for 10-xxZi Module

Data Storage Software

LM10Zi-AORM
Advanced Optical Recording Measurements Software Package for LabMaster 10 Zi
LM10Zi-DDA
Disk Drive Analysis Software Package for LabMaster 10 Zi Series
LM10Zi-DDM2
Disk Drive Measurements Software Package for LabMaster 10 Zi Series

Mixed Signal Accessories

HDA-DLS-18QL
18 channel QuickLink leadset for HDA125
HDA-DLS-09QL
9 channel QuickLink leadset for HDA125

Serial Data Test Fixtures

TF-AUTO-ENET
Automotive Ethernet Breakout Test Fixture for 100Base-T1 and 1000Base-T1 Debug
TF-AUTO-ENET-SMA
4 pack of SMA Connector boards for TF-AUTO-ENET
TF-HDMI-3.3V-QUADPAK
HDMI Pull-Up Terminator Quad Pack - For Use with the Wilder-Tech HDMI-TPA-P Plug Test Adapter
TF-MIPI-MPHY-DUALPAK
MIPI M-PHY input offset adapter dual pack
TF-NBASE-T
TF-NBASE-T supports both NBase-T and 10GBase-T compliance testing. It breaks out the A, B, C and D pairs from the Ethernet cable to SMA connectors. The kit includes power splitter (2) for adding the disturbing signal (for 2.5GBase-T), 50 Ohm terminators (6), Ethernet cables (2), SMA/SMA cables (2) and SMA/BNC cables (4) needed for testing.
TF-PCIE4-CTRL
PCIe 4.0 compliance baseboard test automation controller
TF-SATA-C-Kit
SATA Compliance Test Kit
TF-USB-C-HS
USB4 High-speed and Sideband Test Coupon Fixture
TF-USB-C-SB
USB4 Sideband Test Coupon Fixture
TF-USB3
SuperSpeed and SuperSpeedPlus USB Test Fixtures

Serial Trigger Hardware

LM10Zi-14GBIT-80B-SYMBOL-TD
80-bit NRZ, 8b/10b, and 64b/66b 14.1 Gbps Serial Trigger option for LabMaster 10 Zi Limited Availability

60 V Common Mode Differential Probes

DL-HCM-Acc-Kit
DL-HCM series accessories kit with probe holder, micro IC grabbers (Qty 2.), and Y-banana adaptor.
DL-HCM-HiTemp
DL-HCM series high-temperature solder-in tip, 30 MHz bandwidth, 1 meter length.
DL02-HCM
250 MHz 60 V Common Mode Differential Probe. Includes standard set of leads and tips.
DL05-HCM
500 MHz 60 V Common Mode Differential Probe. Includes standard set of leads and tips.
DL10-HCM
1 GHz 60 V Common Mode Differential Probe. Includes standard set of leads and tips.

Active Voltage Rail Probe

RP2060
Power/Voltage Rail Probe. 2 GHz bandwidth, 1.2x attenuation, +/-60V offset, +/-800mV Includes a complete set of solder-in leads and coaxial cables. Browser tip sold seperately
RP4000-BROWSER
RP2060/RP4060 Browser Tip accessory. Includes 0 Ohm (1x), 450 Ohm (10x) and 950 Ohm (20x) tips.
RP4000-MCX-LEAD-SI
Qty 3 MCX 4 GHz solder-in lead accessories (additional to those supplied with rail probe) 18cm long
RP4030
Power/Voltage Rail Probe. 4 GHz bandwidth, 1.2x attenuation, +/-30V offset, +/-800mV Includes a complete set of solder-in leads, coaxial cables, and PCB mounts. Limited Availability
RP4060
Power/Voltage Rail Probe. 4 GHz bandwidth, 1.2x attenuation, +/-60V offset, +/-800mV Includes a complete set of solder-in leads and coaxial cables. Browser tip sold seperately

Differential Probes (8-30 GHz)

DH-HITEMP
DH series high-temperature solder-in tip, 16 GHz BW, 3.5 Vpp range
DH-PT
DH series PT browser tip, 16 GHz BW, 3.5 Vpp range
DH-QL
DH series QuickLink adapter, 8 GHz BW
DH-QL-3SI
DH series QuickLink adapter kit with 3 x QL-SI tips
DH-SI
DH series solder-in tip, 30 GHz BW, 3.5 Vpp range
DH-SI-HS
DH series high-sensitivity solder-in tip, 30 GHz BW, 2.0 Vpp range

Probe Parts and Kits

OE695G-REFCAL
OE695G Reference Cal (1ch)

Probe Adapters

L2.92A-PBUS
2.92mm to ProBus Adapter with Probe Power and Communication Pass Through
L2.92A-PLINK
2.92mm to ProLink Adapter with Probe Power and Communication Pass Through