Products
Oscilloscopes
SDA 813Zi-B Oscilloscope

SDA 813Zi-B

13 GHz, 40 GS/s, 4ch, 64 Mpts/Ch Serial Data Analyzer with 15.3" WXGA Color Display. 50 ohm and 1 Mohm Input, 6.5 Gb/s Serial Trigger, 8b/10b and 64b/66b decode.


  • product line tab
  • overview tab
  • specs tab
  • options tab
  • probes tab
WaveMaster 804Zi-B  (4 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Limited Availability
Quick Specs
Sample Rate40 GS/s
(80 GS/s on 2 Ch using optional WM8Zi-2X80GS External Interleaving Device)
Maximum Acquisition Memory256 Mpts/Ch
Input Channels4
Vertical Resolution8-bits
WaveMaster 806Zi-B  (6 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Limited Availability
Quick Specs
Sample Rate40 GS/s
(80 GS/s on 2 Ch using optional WM8Zi-2X80GS External Interleaving Device)
Maximum Acquisition Memory256 Mpts/Ch
Input Channels4
Vertical Resolution8-bits
WaveMaster 808Zi-B  (8 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Limited Availability
Quick Specs
Sample Rate40 GS/s
(80 GS/s on 2 Ch using optional WM8Zi-2X80GS External Interleaving Device)
Maximum Acquisition Memory256 Mpts/Ch
Input Channels4
Vertical Resolution8-bits
WaveMaster 813Zi-B  (13 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Limited Availability
Quick Specs
Sample Rate40 GS/s
(80 GS/s on 2 Ch using optional WM8Zi-2X80GS External Interleaving Device)
Maximum Acquisition Memory256 Mpts/Ch
Input Channels4
Vertical Resolution8-bits
WaveMaster 816Zi-B  (16 GHz Bandwidth, 4 Input Channels, 80 GS/s Max Sample Rate)
Limited Availability
Quick Specs
Sample Rate40 GS/s on 4 Ch
80 GS/s on 2 Ch
Maximum Acquisition Memory256 Mpts/Ch
Input Channels4
Vertical Resolution8-bits
SDA 804Zi-B  (4 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Limited Availability
Quick Specs
Sample Rate40 GS/s
(80 GS/s on 2 Ch using optional WM8Zi-2X80GS External Interleaving Device)
Maximum Acquisition Memory256 Mpts/Ch
Input Channels4
Vertical Resolution8-bits
SDA 806Zi-B  (6 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Limited Availability
Quick Specs
Sample Rate40 GS/s
(80 GS/s on 2 Ch using optional WM8Zi-2X80GS External Interleaving Device)
Maximum Acquisition Memory256 Mpts/Ch
Input Channels4
Vertical Resolution8-bits
SDA 808Zi-B  (8 GHz Bandwidth, 4 Input Channels, 32 GS/s Max Sample Rate)
Limited Availability
Quick Specs
Sample Rate40 GS/s
(80 GS/s on 2 Ch using optional WM8Zi-2X80GS External Interleaving Device)
Maximum Acquisition Memory256 Mpts/Ch
Input Channels4
Vertical Resolution8-bits
SDA 813Zi-B  (13 GHz Bandwidth, 4 Input Channels, 40 GS/s Max Sample Rate)
Limited Availability
Quick Specs
Sample Rate40 GS/s
(80 GS/s on 2 Ch using optional WM8Zi-2X80GS External Interleaving Device)
Maximum Acquisition Memory256 Mpts/Ch
Input Channels4
Vertical Resolution8-bits
SDA 816Zi-B  (16 GHz Bandwidth, 4 Input Channels, 80 GS/s Max Sample Rate)
Limited Availability
Quick Specs
Sample Rate40 GS/s on 4 Ch
80 GS/s on 2 Ch
Maximum Acquisition Memory256 Mpts/Ch
Input Channels4
Vertical Resolution8-bits
Check up to three models.
Key Features
  • Up to 20 GHz bandwidth and 80 GS/s sample rate
  • The most advanced oscilloscope user interface
  • The industry’s only true hardware 14.1 Gb/s serial trigger
  • Low Jitter Measurement Floor and exceptional timebase stability
  • Comprehensive set of serial data analysis, debug, validation and compliance tools
  • Integrated 50 Ω and 1 MΩ inputs for true connection and probing flexibility
  • Integrated standard and custom measurements and math functions for unrivaled analysis capability
  • Multi-lane serial data eye, jitter and crosstalk analysis
  • Real-time de-embedding, emulation, and equalization

 

Exceptional Performance

With up to 20 GHz bandwidth, 80 GS/s sample rate, extremely stable timebase and a 14.1 Gb/s serial trigger the WaveMaster 8 Zi-B has the hardware performance to capture today’s high-speed signals.

Revolutionary Usability

The WaveMaster 8Zi-B is a sophisticated instrument, designed for solving complex problems. But the MAUI user interface, along with the WaveMaster 8Zi-B’s 15.3” high-resolution touchscreen, makes advanced analysis easy to set up and use. A flat menu structure puts the most common tools in the easiest reach. Sophisticated multi-grid displays are easy to configure. Vertical, horizontal and acquisition setting changes are made without obscuring waveform display.

Made to Solve

MAUI provides the most tightly-integrated toolset of any oscilloscope user interface. Track measured parameters across acquisitions, trend their variations on longer timescales, or visualize and measure their distributions using histograms. Chain multiple measurements and math functions together to easily create custom analysis features for your applications. Integrate third-party programming environments, such as MATLAB, directly into the scope’s processing stream for even more customization.

Debug and Validation Made Easy

Connecting a problem with its root cause often requires looking at the signal in multiple domains. The WaveMaster 8Zi-B allows you to combine multiple analysis types into a single, correlated display: analog signals, protocol decodes, eye diagrams, measurement parameters, and other relevant information are presented side-by-side, in real-time.

Configurations Optimized for Serial Data Analysis

The SDA 8 Zi-B models have been specifically configured to handle today’s most challenging serial data applications. As well as doubling the standard memory depth, the SDA 8 Zi-B comes as standard with the SDAIII core toolset, which provides tightly-integrated and comprehensive eye diagram and jitter analysis for NRZ signals.

SDAIII toolset

The Teledyne LeCroy SDAIII-CompleteLinQ Serial Data Analysis products contain multilane eye and jitter analysis, LaneScape™ comparison modes, vertical noise measurements, and crosstalk analysis tools. These capabilities provide the deepest insight into the behavior of multi- or single-lane serial data systems.

Decode From Bit-level to Protocol Layer

Decoders are available for over 20 low-speed and high-speed serial data buses. These fully-integrated analysis tools annotate the acquired analog waveform with the corresponding decoded data, as well as providing a comprehensive, exportable decode table.

For many standards, ProtoSync allows a view from even higher up the protocol stack, linking the physical-layer waveforms to full transaction- and protocol-layer analysis.

Automated Compliance Testing

Teledyne LeCroy’s QualiPHY software makes it easy to perform automated compliance tests and produce comprehensive test reports on a wide array of serial standards including:

  • PCI Express (1.0, 2.0, 3.0)
  • USB1, USB2, USB 3.0, USB 3.1
  • DDR2, DDR3, DDR4, DDR5, LPDDR2, LPDDR3, LPDDR4, LPDDR4X
  • SAS2, SAS3, SATA
  • MIPI D-PHY, MIPI M-PHY
  • 10/100/100 BASE-T, 10GBASE-T, 10GBASE-KR, SFI
  • HDMI 1.4, HDMI 2.0, DisplayPort 1.2
  • MOST50, MOST150, BroadR-Reach

 

Vertical - Analog Channels

Analog Bandwidth (Max) 13 GHz
Bandwidth 13 GHz
Analog Bandwidth @ 50 Ω (-3 dB) (ProLink Input) 13 GHz
(≥10 mV/div)
Analog Bandwidth @ 50 Ω (-3 dB) (ProBus Input) 3.5 GHz
(≥10 mV/div)
Analog Bandwidth @ 1 MΩ (-3 dB) (ProBus Input) 500 MHz (typical, ≥2 mV/div)
Rise Time (10-90%, 50 Ω) 32.5 ps
(test limit, flatness mode)
Rise Time (20-80%, 50 Ω) 24.5 ps
(flatness mode)
Input Channels 4 (Any combination of ProLink and ProBus inputs)
Vertical Resolution 8 bits; up to 11 bits with enhanced resolution (ERES)
Vertical Noise Floor (50 mV/div) 1.21 mVrms (typical)
Sensitivity 50 Ω (ProLink): 2 mV-1 V/div, fully variable (2-9.9 mV/div via zoom)
50 Ω (ProBus): 2 mV-1 V/div, fully variable; 1 MΩ (ProBus): 2 mV-10 V/div, fully variable
DC Vertical Gain Accuracy (Gain Component of DC Accuracy) ±1% F.S. (typical), offset at 0V; ±1.5% F.S. (test limit), offset at 0V
Channel-Channel Isolation DC to 10 GHz: 50 dB (>315:1)
10 to 15 GHz: 46 dB (>200:1)
15 to 20 GHz: 40 dB (>100:1)
(For any two ProLink input channels, same or different v/div settings, typical)
Offset Range 50 Ω (ProLink):
±500 mV @ 2-100 mV/div
±4 V @ >100 mV/div -1 V/div
50 Ω (ProBus):
±750 mV @ 2-100 mV/div
±4 V @ >100 mV/div -1 V/div
1 MΩ:
±1V @ 2-140 mV/div
±10V @ 142mV-1.40V/div
±100V @ 1.42V-10V/div
DC Vertical Offset Accuracy ±(1.5% of offset setting + 1.5% F.S. + 1 mV) (test limit)
Maximum Input Voltage 50 Ω (ProLink): ±2 Vmax@≤100mV/div, 5.5Vrms@>100mV/div
50 Ω (ProBus): ±5 Vmax, 3.5 Vrms
1 MΩ (ProBus): 250 V max. (peak AC: < 10 kHz + DC)
Input Coupling ProLink Inputs - 50 Ω: DC, GND
ProBus Inputs - 1 MΩ: AC, DC, GND; 50 Ω: DC, GND
Input Impedance ProLink Inputs: 50 Ω+/-2% for ≤100 mV/div, 50 Ω+/-3% for >100 mV/div
ProBus Inputs: 50 Ω+/-2% or 1 MΩ||16pF, 10 MΩ || 11 pF with supplied Probe
Bandwidth Limiters 20 MHz, 200 MHz, 1 GHz, 4 GHz, 6 GHz, 8 GHz
Rescaling Length: meters, inches, feet, yards, miles; Mass: grams, slugs; Temperature: celsius, fahrenheit, kelvin; Angle: radian, arcdegr, arcmin, arcsec, cycles, revolutions, turns; Velocity: m/s, in/s, ft/s, yd/s, miles/s; Acceleration: m/s2, in/s2, ft/s2, g0; Volume: liters, cubic meters, cubic inches, cubic feet, cubic yards; Force (Weight): newton, grain, ounce, pound; Pressure: pascal, bar, atmosphere (technical), atmosphere (standard), torr, psi; Electrical: volts, amps, watts, volt-amperes, volt-amperes reactive, farad, coulomb, ohm, siemen, volt/meter, coulomb/m2, farad/meter, siemen/meter, power factor; Magnetic: weber, tesla, henry, amp/meter, henry/meter; Energy: joule, Btu, calorie; Rotating Machine: radian/second, frequency, revolution/second, revolution/minute, N m, lb-ft, lb-in, oz-in, watt, horsepower; Other: %.
 

Horizontal - Analog Channels

Timebases Internal timebase common to 4 input channels
Time/Division Range 20 ps/div-128 s/div (Real-Time Mode: 20 ps/div - 64 s/div; RIS mode: 20 ps/div - 10 ns/div, user selectable at ≤10ns/div; Roll mode: 100 ms/div up to 128 s/div, user selectable at ≥100 ms/div and ≤5 MS/s), depending on memory length
Clock Accuracy < 1 ppm + (aging of 0.5ppm/yr from last calibration)
Sample Clock Jitter up to 10µs Acquired Time Range:
100fsrms (Internal Timebase Reference)

up to 6.4ms Acquired Time Range:
150fsrms (Internal Timebase Reference)
Delta Time Measurement Accuracy \sqrt{2}*\sqrt{(\frac{Noise}{SlewRate})^2+(Sample Clock Jitter)^2) (RMS)+(clock accuracy*reading)(seconds)
Jitter Measurement Floor \sqrt{(\frac{Noise}{SlewRate})^2+(Sample Clock Jitter)^2\; seconds\; rms\; (TIE)}
Jitter Between Channels <325fsrms
(TIE, typical, measured at maximum bandwidth)
Channel-Channel Deskew Range ±9 x time/div. setting or 25 ns max. (whichever is larger), each channel
External Timebase Reference (Input) 10 MHz; 50 Ω impedance, applied at the rear input
External Timebase Reference (Output) 10 MHz; 50 Ω impedance, output at the rear
 

Acquisition - Analog Channels

Sample Rate (Single-shot) 40 GS/s
(80 GS/s on 2 Ch using optional WM8Zi-2X80GS External Interleaving Device)
Sample Rate (Repetitive) 200 GS/s for repetitive signals (20 ps/div to 10 ns/div)
Memory Length (4 Ch / 2 Ch / 1Ch)
(Number of Segments)
64 M / 64 M / 64 M
(Memory and Sample Rate can be doubled in 1 or 2 Ch mode with use of WM8Zi-2X80GS External Interleaving Device)
(15000)
Memory Length Options (4 Ch / 2 Ch / 1Ch)
(Number of Segments)
L-128 Option:
128M / 128M / 128M
(15,000)
VL-256 Option:
256M / 256M / 256M
(15,000)
Note: On all memory options, WM8Zi-2X80GS External Interleaving Device permits 80 GS/s on 1 or 2ch with twice the memory)
Intersegment Time 1 µs
Averaging Summed averaging to 1 million sweeps; continuous averaging to 1 million sweeps
Enhanced Resolution (ERES) From 8.5 to 11 bits vertical resolution
Envelope (Extrema) Envelope, floor, or roof for up to 1 million sweeps
Interpolation Linear or Sin x/x
 

Triggering System

Max Trigger Frequency (C1-C4, Aux In, SMART Trigger) 2.0 GHz @ ≥ 10 mV/div (minimum triggerable width 200 ps)
Modes Normal, Auto, Single, and Stop
Sources Any input channel, Aux, Aux/10, Line, or Fast Edge. Slope and level unique to each source (except line trigger)
Coupling DC, AC, HFRej, LFRej
Pre-trigger Delay 0-100% of memory size (adjustable in 1% increments of 100 ns)
Post-trigger Delay 0-10,000 divisions in real time mode, limited at slower time/div settings or in roll mode
Hold-off From 2 ns up to 20 s or from 1 to 99,999,999 events
Trigger and Interpolator Jitter <0.1 ps rms (typical, software assisted), 2 ps rms (typical, hardware),
Internal Trigger Level Range ±4.1 div from center
External Trigger Level Range Aux (±0.4 V); Aux/10 (±4 V)
Maximum Trigger Rate 1,000,000 waveforms/second (in Sequence Mode, up to 4 channels)
Trigger Sensitivity with Edge Trigger ProLink Inputs 3 div @ < 13 GHz,
1.5 div @ < 3 GHz,
1.0 div @ < 200 MHz,
(for DC, AC, LFRej coupling, ≥ 10 mV/div, 50 Ω )
Trigger Sensitivity with Edge Trigger ProBus Inputs 2 div @ < 3.5 GHz,
1.5 div @ < 1.75 GHz,
1.0 div @ < 200 MHz,
(for DC coupling, ≥ 10 mV/div, 50 Ω )
Trigger Sensitivity with Edge Trigger (Aux Input) 2 div @ < 1 GHz,
1.5 div @ < 500 MHz,
1.0 div @ < 200 MHz,
(for DC coupling)
 

Trigger Types

Edge Triggers when signal meets slope (positive, negative, or either) and level condition.
Width Triggers on positive, negative, or both widths with widths selectable as low as 200ps to 20 s, or on intermittent faults.
Glitch Triggers on positive or negative glitches with widths selectable as low as 200ps to 20 s, or on intermittent faults.
Window Triggers when signal exits a window defined by adjustable thresholds
Pattern Logic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input). Each source can be high, low, or don’t care. The High and Low level can be selected independently. Triggers at start or end of the pattern.
TV-Composite Video Triggers NTSC or PAL with selectable line and field; HDTV (720p, 1080i, 1080p) with selectable frame rate (50 or 60 Hz) and Line; or CUSTOM with selectable Fields (1-8), Lines (up to 2000), Frame Rates (25, 30, 50, or 60 Hz), Interlacing (1:1, 2:1, 4:1, 8:1), or Synch Pulse Slope (Positive or Negative).
Runt Trigger on positive or negative runts defined by two voltage limits and two time limits. Select between 1 ns and 20 ns.
Slew Rate Trigger on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 ns.
Interval Triggers on intervals selectable between 1 ns and 20 s.
Dropout Triggers if signal drops out for longer than selected time between 1 ns and 20 s.
Measurement Trigger Select from a large number of measurement parameters trigger on a measurement value with qualified limits. Can be used as only trigger or last event in a Cascade Trigger.
Multi-Stage: Qualified (Timeout or State/Edge Qualified) Triggers on any input source only if a defined state or edge occurred on another input source. Holdoff between sources is selectable by time or events.
Triggers with Exclusion Technology Trigger on intermittent faults by specifying the expected behavior and triggering when that condition is not met
Multi-Stage: Qualified First In Sequence acquisition mode, triggers repeatably on event B only if a defined pattern, state, or edge (event A) is satisfied in the first segment of the acquisition. Holdoff between sources is selectable by time or events.
Multi-Stage: Cascade (Sequence) Trigger, Capability Arm on A event, then Trigger on B event. Or Arm on A event, then Qualify on B event, and Trigger on C event.
Multi-Stage: Cascade (Sequence) Trigger, Types Cascade A then B: Edge, Window, Pattern (Logic) Width, Glitch, Interval, Dropout, or Measurement. Measurement can be on Stage B only.
Cascade A then B then C (Measurement): Edge, Window, Pattern (Logic), Width, Glitch, Interval, Dropout, or Measurement. Measurement can be on Stage C only.
Cascade A then B then C: Edge, Window, Pattern (Logic)
Multi-Stage: Cascade (Sequence) Trigger, Holdoff Holdoff between A and B or B and C is selectable by time or number of events.
Measurement trigger selection as the last stage in a Cascade precludes a holdoff setting between the prior stage and the last stage.
 

Low Speed Serial Protocol Trigger (Optional)

Supported Protocols I2C, SPI (SPI, SSPI, SIOP), UART-RS232, CAN, LIN, FlexRay, I2S (Audio), MIL-1553
 

High Speed Serial Protocol Trigger

Data Rates Option WM8Zi-6GBIT-80B-SYMBOL-TD:
600 Mb/s to 6.5 Gb/s, Channel 4 input only
Option WM8Zi-14GBIT-80B-SYMBOL-TD:
600 Mb/s to 14.1 Gb/s, Channel 4 input only
Pattern Length 80 bits NRZ, eight 8b/10b symbols, 64b/66b symbol
 

Display System

Size Color 15.3 flat panel TFT-Active Matrix LCD with high resolution touch screen
Resolution WXGA; 1280 x 768 pixels.
Number of traces Display a maximum of 16 traces (up to 40 with some software options). Simultaneously display channel, zoom, memory and math traces.
Grid Styles Auto, Single, Dual, Quad, Octal, X-Y, Single+X-Y, Dual+X-Y
Waveform Representation Sample dots joined, or sample dots only
 

Integrated Second Display

Size Supports touch screen integration of user-supplied second display with split-grid capability.
(Note: touch screen driver for second display may not be a Fujitsu driver)
Resolution Determined by display chosen by user
 

LeCroy WaveStream™ Fast Viewing Mode

Intensity 256 Intensity Levels, 1-100% adjustable via front panel control
Types Select analog or color-graded
Number of Channels up to 4 simultaneously
Max Sampling Rate 40 GS/s (80 GS/s with optional WM8Zi-2X80GS external interleaving device)
Persistence Aging Select from 500 ms to Infinity
Waveforms/second (continuous) up to 2500 Waveforms/second
Operation Front panel toggle between WaveStream ON (Analog), ON (Color) and OFF
 

Persistence Display

Analog and Color-Graded Persistence Variable saturation levels; stores each trace’s persistence data in memory
Persistence Types Select analog, color, or three-dimensional
Trace Selection Activate persistence on all or any combination of traces
Persistence Aging Select from 500 ms to infinity
Sweep Display Modes All accumulated, or all accumulated with last trace highlighted
 

High Speed Digitizer Output (Option)

Type LeCroy LSIB
Transfer Rate up to 325 MB/s (typical)
Output Protocol PCI Express, Gen 1 (4 lanes utilized for data transfer)
Control Protocol TCP/IP
Command Set Via Windows Automation, or via LeCroy Remote Command Set
 

Zoom Expansion Traces

Zoom Expansion Traces Display up to 12 Zoom and 12 Math/Zoom traces
 

Internal Waveform Memory

Internal Waveform Memory 12 active waveform memory traces (M1-M12) store 16 bit/point full length waveforms. Waveforms can be stored to any number of files limited only by the data storage media capacity.
 

Setup Storage

Front Panel and Instrument Status Store to the internal hard drive, over the network, or to a USB-connected peripheral device.
 

Automatic Setup

Auto Setup Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals
Find Vertical Scale Automatically sets the vertical sensitivity and offset for the selected channel to display a waveform with the maximum dynamic range
 

Calibration

Auto Calibration Ensures specified DC and timing accuracy is maintained for 1 year minimum.
 

Processor/CPU

Type Intel® CoreTM i7-4770S Quad, 3.1 GHz (up to 3.9 GHz in Turbo mode) (or better)
Processor Memory 16 GB standard for STD memory (64 Mpt) memory option
32 GB standard for L-128 and VL-256 memory options
Operating System Microsoft Windows® 10
Oscilloscope Operating Software Teledyne LeCroy MAUI™ with OneTouch
Real Time Clock Date and time displayed with waveform in hardcopy files. SNTP support to synchronize to precision internal clocks.
 

Connectivity

Ethernet Port Supports 10/100/1000BaseT Ethernet interface (RJ45 port)
USB Host Ports 4 rear USB 3.0 ports, 3 front panel USB 2.0 ports support Windows compatible devices
GPIB Port (optional) Supports IEEE - 488.2
External Monitor Port Full-size DisplayPort connnector
Includes support for extended desktop operation with second monitor.
Remote Control Via Windows Automation, or via LeCroy Remote Command Set
Network Communication Standard VXI-11 or VICP, LXI Class C (v1.2) Compliant
LSIB Port (optional) Supports PCIe Gen1 x4 protocol with LeCroy supplied API
Peripheral Bus Teledyne LeCroy LBUS standard
 

Auxiliary Input

Signal Types For External Trigger Input
Coupling 50 Ω: DC; 1 MΩ: AC, DC, GND
Max. Input Voltage 50 Ω: 5 Vrms; 1 MΩ: 250 V (Peak AC < 10 kHz + DC)
 

Auxiliary Output

Signal Types Select from calibrator, control signals or Off
Output Signal 500 Hz-5 MHz square wave or DC level; 0.0 to 500 mV into 50 Ω (0-1 V into 1 MΩ)
Control Signals Trigger enabled, trigger out, pass/fail status, off
Connector Type BNC, located on front
 

Probes

Probing System Probus and ProLink. Automatically detects and supports a variety of compatible probes
Probes Qty. (4) ÷10 Passive Probes
Scale Factors Automatically or manually selected depending on probe used
Calibration Output Cal Output: 1kHz square wave, 1Vp-p (typical), output to probe hook.
Fast Edge output: 5MHz square wave, 350mVp-p (typical), 50ps rise time, output to SMA connector, AC Coupled.
 

Power Requirements

Voltage 100-240 VAC ±10% at 45-66 Hz; 100-120 VAC ±10% at 380-420 Hz; Automatic AC Voltage Selection, Installation Category II
Max. Power Consumption 975 W / 975 VA
 

Environmental

Temperature (Operating) +5 °C to +40 °C
Temperature (Non-Operating) -20 °C to +60 °C
Humidity (Operating) 5% to 80% relative humidity (non-condensing) up to +31 °C.
Upper limit derates to 50% relative humidity (non-condensing) at +40 °C.
Humidity (Non-Operating) 5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F
Altitude (Operating) Up to 10,000 ft. (3048 m) at or below +25 °C
Altitude (Non-Operating) Up to 40,000 ft. (12,192 m)
Random Vibration (Operating) 0.5 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Random Vibration (Non-Operating) 2.4 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes
Functional Shock 20 g peak, half sine, 11 ms pulse, 3 shocks (positive and negative) in each of three orthogonal axes, 18 shocks total
 

Size and Weight

Dimensions (HWD) 14H x 18.4W x 16D (355 x 467 x 406 mm)
Weight 51.5 lbs. (23.4 kg)
Shipping Weight 70.0 lbs. (31.8 kg)
 

Certifications

CE Certification
UL and cUL Listing
CE Compliant, UL and cUL listed; conforms to EN 61326, EN 61010-1, EN61010-2-030, UL 61010-1 3rd edition, and CSA C22.2 No. 61010-1-12
 

Warranty and Service

Warranty and Service 3-year warranty; calibration recommended annually.
Optional service programs include extended warranty, upgrades, and calibration services.
 

Mixed Signal Solutions

HDA125-09-LBUS
12.5 GS/s High-speed Digital Analyzer with 9ch QuickLink leadset and LBUS connection
HDA125-18-LBUS
12.5 GS/s High-speed Digital Analyzer with 18ch QuickLink leadset and LBUS connection

Memory Options

SDA8Zi-L-128
128 Mpt/Ch (4 channel operation) Memory Option for SDA 8 Zi-A. Incl. 32 GB CPU RAM standard.
SDA8Zi-VL-256
256 Mpt/Ch (4 channel operation) Memory Option for SDA 8 Zi-A. Incl. 32 GB CPU RAM standard.

Sampling Rate Options

WM8Zi-2X80GS
80 GS/s on 2ch Sampling Rate Option for WaveMaster/SDA/DDA 8 Zi and 8Zi-A (not available for 820Zi, 825Zi/Zi-A, 830Zi/Zi-A, 9x30Zi-A, 845Zi-A or 9x45Zi-A). Includes two separate external interleaving devices with storage case.

Remote Control/Network Options

USB2-GPIB
External USB 2.0 to GPIB IEEE 488.2 adapter

Power Analysis Software

WM8Zi-PWR
Power Analysis Option for WM 8 Zi

Serial Trigger and Decode

WM8Zi-1000BASE-T1 TDMP
1000Base-T1 Trigger, Decode, Measure/Graph, and Physical Layer Option for WaveMaster/SDA 8 Zi/-A/-B
WM8Zi-100BASE-T1 TDMP
100Base-T1 Trigger, Decode, Measure/Graph, and Physical Layer Option for WaveMaster/SDA 8 Zi/-A/-B
WM8ZI-QSPI D
QSPI (Simple Data, Dual-, Quad-SPI) Decode Option for WM8Zi-Serie
WM8Zi-100Base-T1bus TD
100Base-T1 Trigger and Decode Option for WaveMaster/SDA 8 Zi/-A/-B
WM8ZI-USB4BUS DME
USB4 and TBT4 Decode, Measure/Graph, and Eye Measurements Option for WaveMaster/SDA/DDA 8 Zi/-A/-B
WM8Zi-1553 TD
MIL-STD-1553 Trigger and Decode Option for WaveMaster/SDA/DDA 8 Zi/-A/-B and 8Zi-A Oscilloscopes and Analyzers
WM8ZI-1553 TDME
MIL-STD-1553 Trigger, Decode, Measure/Graph, and Eye Diagram Opt. for WaveMaster/SDA/DDA 8 Zi/-A/-B
WM8Zi-64b66b D
64b66b Decode Option
WM8Zi-10BASE-T1S TDME
10Base-T1S Trigger, Decode, Measure/Graph, and Eye Diagram Option for WaveMaster 8Zi
WM8ZI-USB4SB TDMP
USB4/TBT4 SB Trigger, Decode, Measure/Graph, and PHY Meas. Option for WaveMaster/SDA/DDA 8 Zi/-A/-B
WM8Zi-6GBIT-80B-SYMBOL-TD
80-bit NRZ, 8b/10b, and 64b/66b 6.5 Gbps Serial Trigger option for WaveMaster 8 Zi-A and DDA 8 Zi-A Limited Availability
WM8Zi-10BASE-T1S TD
10Base-T1S Trigger and Decode Option for WaveMaster/SDA/DDA 8 Zi/-A/-B
WM8ZI-USB4SB TD
USB4 and Thunderbolt Sideband Trigger and Decode Option for WaveMaster/SDA/DDA 8 Zi/-A/-B
WM8Zi-ARINC429BUS DME SYMBOLIC
ARINC 429 Bus Symbolic Decode, Measure/Graph, and Eye Diagram Opt. for WM/SDA/DDA 8 Zi/-A/-B
WM8Zi-ARINC429bus DSymbolic
ARINC 429 Bus Symbolic Decode option for WaveMaster/SDA/DDA 8 Zi/-A/-B
WM8Zi-AudioBus TD
AudioBus trigger and decode for WaveMaster/SDA/DDA 8Zi and 8Zi-A Oscilloscopes and Analyzers
WM8Zi-AudioBus TDG
AudioBus trigger, decode, and graph for WaveMaster/SDA/DDA 8Zi and 8Zi-A Oscilloscopes and Analyzers
WM8Zi-CAN FDbus TD
CAN and CAN FD Trigger and Decode Option for WaveMaster/SDA/DDA 8 Zi/-A/-B Oscilloscopes
WM8ZI-CAN FDBUS TDME SYMBOLIC
CAN/CAN FD Symbolic Trigger, Decode, Measure/Graph, and Eye Diagram Opt. for WM/SDA/DDA 8 Zi/-A/-B
WM8Zi-CPHYBUS D
C-PHY (DSI-2/CSI-2) Decode Opt. for WaveMaster/SDA/DDA 8Zi/-A/-B
WM8Zi-CPHYBUS DMP
C-PHY (DSI-2/CSI-2) Decode, Measure/Graph and Physical Layer Opt. for WaveMaster/SDA/DDA 8Zi/-A/-B
WM8Zi-DigRF3Gbus D
DigRF 3G Bus Decode option for WaveMaster 8Zi
WM8Zi-DigRFV4bus D
DigRF V4 Bus Decode option for WaveMaster 8Zi series
WM8ZI-DPAUX D
DisplayPort AUX Decode Option for WaveMaster/SDA/DDA 8 Zi/-A/-B
WM8ZI-DPAUX DMP
DisplayPort AUX Decode, Measure/Graph, and Physical Layer Opt for WaveMaster/SDA/DDA 8 Zi/-A/-B
WM8Zi-DPHYbus D
D-PHY Bus Decode option for WaveMaster 8Zi
WM8Zi-DPHYbus DP
MIPI D-PHY CSI-2, DSI Bus Decode and Physical Layer test option for WaveMaster 8Zi series
WM8ZI-EMB TD
Bundle: Includes I2C, SPI, UART-RS232 Trigger and Decode Options for for WM/SDA/DDA 8 Zi/-A/-B
WM8ZI-EMB TDME
Bundle: Incl. I2C, SPI, UART-RS232 Trigger, Decode, Measure/Graph, and Eye Diag Opt. for 8 Zi/-A/-B
WM8ZI-EMB TDME
Bundle: Incl. I2C, SPI, UART-RS232 Trigger, Decode, Measure/Graph, and Eye Diag Opt. for 8 Zi/-A/-B
WM8Zi-ENET10Gbus D
ENET 10G Decode Option
WM8Zi-ENETbus D
ENET Bus Decode Option for WaveMaster 8Zi
WM8Zi-FCbus D
FibreChannel decode annotation option for WaveMaster 8Zi series
WM8Zi-FlexRayBus TD
FlexRay Trigger and Decode Option for WaveMaster/SDA/DDA 8 Zi/-A/-B and Analyzers
WM8ZI-FLEXRAYBUS TDMP
FlexRay Trigger, Decode, Measure/Graph and Physical Layer Option for WaveMaster/SDA/DDA 8 Zi/-A/-B
WM8Zi-I2Cbus TD
I2C Trigger and Decode Option for WaveMaster/SDA/DDA 8 Zi/-A/-B Oscilloscopes and Analyzers
WM8ZI-I2CBUS TDME
I2C Trigger, Decode, Measure/Graph, and Eye Diagram Option for for WaveMaster/SDA/DDA 8 Zi/-A/-B
WM8Zi-LINbus TD
LIN Trigger and Decode Option for WaveMaster/SDA/DDA 8 Zi/-A/-B Oscilloscopes and Analyzers
WM8ZI-LINBUS TDME
LIN Trigger, Decode, Measure/Graph, and Eye Diagram Option for WaveMaster/SDA/DDA 8 Zi/-A/-B
WM8Zi-Manchesterbus D
Manchester Bus Decode Option for WaveMaster 8Zi
WM8Zi-MDIObus D
MDIO Decode for WaveMaster/SDA/DDA 8Zi/Zi-A/Zi-B Series
WM8Zi-MPHYbus D
MIPI M-PHY Bus Decode option for WaveMaster 8Zi series
WM8Zi-MPHYbus DP
MIPI M-PHY Bus Decode and Physical Layer test option for WaveMaster 8Zi series
WM8ZI-MSO-EMB TDME
Bundle: MS-500-36 w I2C, SPI, UART-RS232 Trig, Decode, Measure/Graph and EyeDiag Opt for 8 Zi/-A/-B
WM8ZI-MSO-EMB TDME
Bundle: MS-500-36 w I2C, SPI, UART-RS232 Trig, Decode, Measure/Graph and EyeDiag Opt for 8 Zi/-A/-B
WM8Zi-PCIEbus D
PCI Express Protocol Link Layer Decode Annotation for WaveMaster/SDA/DDA 8Zi and 8Zi-A Oscilloscopes and Analyzers
WM8Zi-ProtoSync
Decode Annotation and Protocol Analyzer Software Synchronization Option for WaveMaster 8Zi/Zi-A
WM8Zi-ProtoSync-BT
Decode Annotation and Protocol Analyzer+Bit Tracer SW Synchronization Option for WaveMaster 8Zi/Zi-A
WM8Zi-SASbus D
SAS Decode annotation option for WaveMaster 8Zi series
WM8Zi-SATAbus D
SATA Decode option for WaveMaster 8Zi Supports SATA Gen 1, 2, and 3.
WM8ZI-SENTbus D
SENT Bus Decode Option for WaveMaster 8Zi
WM8Zi-SpaceWirebus D
SpaceWire Decode Option for WaveMaster 8Zi series
WM8Zi-SPIbus TD
SPI Trigger and Decode Option for WaveMaster/SDA/DDA 8 Zi/-A/-B Oscilloscopes and Analyzers
WM8ZI-SPIBUS TDME
SPI Trigger, Decode, Measure/Graph, and Eye Diagram Option for WaveMaster/SDA/DDA 8 Zi/-A/-B
WM8Zi-SPMIbus D
SPMI Decode for WaveMaster/SDA/DDA 8Zi/Zi-A/Zi-B Series
WM8Zi-UART-RS232bus TD
UART-RS232 Trigger and Decode Option for WaveMaster/SDA/DDA 8 Zi/-A/-B Oscilloscopes and Analyzers
WM8ZI-UART-RS232BUS TDME
UART-RS232 Trigger, Decode, Measure/Graph, and Eye Diagram Option for WaveMaster/SDA/DDA 8 Zi/-A/-B
WM8ZI-UNIPRObus D
MIPI UniPro Protocol Decoder Software Option
WM8Zi-USB2-HSICbus D
USB 2.0 HSIC Decode Option
WM8Zi-USB2bus D
USB 2.0 Decode Option for WaveMaster/SDA/DDA 8 Zi/-A/-B
WM8ZI-USB2BUS DME
USB 2.0 Decode, Measure/Graph, and Eye Diagram Option for WaveMaster/SDA/DDA 8 Zi/-A/-B
WM8ZI-USB32BUS D
USB 3.2 Decode for for WaveMaster/SDA/DDA 8 Zi/-A/-B
WM8ZI-USBPD TD
USB-PD Trigger and Decode Option for WaveMaster/SDA/DDA 8 Zi/-A/-B
WM8ZI-USBPD TDMP
USB-PD Trigger, Decode, Measure/Graph, and Physical Layer Opt. for WaveMaster/SDA/DDA 8 Zi/-A/-B

Jitter Analysis Software

SDA8ZI-CLOCK-X
Clock Expert Jitter Analysis Framework
SDA8ZI-CLOCK-X-PRO
Clock Expert Jitter Analysis Framework with SSC, Phase Noise and Accumulated Jitter Analysis
WM8Zi-JITKIT
Clock, clock-data Jitter Analysis and views of time, statistical, spectral, and jitter overlay

Digital Filtering Software

WM8Zi-DFP2
Digital Filter Software Package for WaveMaster 8 Zi Series

Serial Data Compliance

WM8Zi-AUTO-ENET-TOOLKIT
100Base-T1 and 1000Base-T1 Debug Toolkit for WaveMaster 8 Zi
WM8ZI-DDR2-TOOLKIT
DDR 2 and LPDDR 2 Debug Toolkit for WaveMaster 8Zi Oscilloscopes
WM8ZI-DDR3-TOOLKIT
DDR 3/2 and LPDDR 3/2 Debug Toolkit for WaveMaster 8Zi Oscilloscopes
WM8ZI-DDR4-TOOLKIT
DDR2/3/4 and LPDDR2/3/4/4X Debug Toolkit for WaveMaster 8Zi Oscilloscopes
WM8ZI-DDR5-TOOLKIT
DDR 2/3/4/5 and LPDDR 2/3/4/4X Debug Toolkit for WaveMaster 8Zi Oscilloscopes
QPHY-1000Base-T1
QualiPHY Enabled 1000Base-T1 (Automotive Ethernet) Compliance Software Option
QPHY-100Base-T1
QualiPHY Enabled 100Base-T1 (Automotive Ethernet) Compliance Software Option
QPHY-10Base-T1L
QualiPHY Enabled 10Base-T1L (Industrial Ethernet) Compliance Software Option
QPHY-10Base-T1S
QualiPHY Enabled 10Base-T1S (Automotive Ethernet) Compliance Software Option
QPHY-10GBase-KR
QualiPHY Enabled 10GBase-KR Compliance Software Option
QPHY-10GBASE-T
QualiPHY Enabled 10GBASE-T Transmitter and Return Loss Compliance Test Software Option
QPHY-DDR2
QualiPHY Enabled DDR2 Compliance Software Option
QPHY-DDR3
QualiPHY Enabled DDR3, DDR3L and LPDDR3 Compliance Software Option
QPHY-DDR4
QualiPHY Enabled DDR4 and LPDDR4 Compliance Software Option
QPHY-DP14-SOURCE
QualiPHY Enabled DisplayPort 1.4 Source Compliance Software Option
QPHY-DP20-SINK
QualiPHY Enabled DisplayPort 2.0 Sink Compliance Software Option
QPHY-DP20-SOURCE
QualiPHY Enabled DisplayPort 2.0 Source Compliance Software Option (Includes QPHY-DP14-SOURCE)
QPHY-eDP
QualiPHY Enabled Embedded DisplayPort Compliance Software Option
QPHY-ENET
QualiPHY Enabled Ethernet 10/100/1000BT Compliance Software Option
QPHY-HDMI2
QualiPHY Enabled HDMI 2.0/1.4b TMDS Compliance Software Option
QPHY-LPDDR2
QualiPHY Enabled LPDDR2 Compliance Software Option
QPHY-MIPI-CPHY
QualiPHY Enabled MIPI C-PHY Compliance Software Option (includes C-PHY DMP)
QPHY-MIPI-DPHY
QualiPHY Enabled MIPI DPHY Compliance Software Option
QPHY-MIPI-MPHY
QualiPHY Enabled MIPI M-PHY Compliance Software Option
QPHY-MOST150
QualiPHY MOST150 oPHY and cPHY Compliance Software Option. Requires options DFP2 and SDM or SDA3
QPHY-MOST50
QualiPHY Enabled MOST50 ePHY Compliance Software Option. Requires options DFP2 and SDM or SDA3
QPHY-MultiGBase-T1
QualiPHY Enabled MultiGBase-T1 (Automotive Ethernet) Compliance Software Option
QPHY-PCIe
QualiPHY Enabled PCIe 2.0 and 1.0 Compliance Software Option Includes PCIe Tx/Rx and CXL Tx electrical tests
QPHY-PCIE3-TX-RX
QualiPHY Enabled PCIe 3.0 through 1.0 Compliance Software Option Includes PCIe Tx/Rx and CXL Tx electrical tests
QPHY-SAS2
QualiPHY Enabled SAS2 (1.5 Gb/s, 3.0 Gb/s, and 6.0 Gb/s) Compliance Software Option
QPHY-SAS3
QualiPHY Enabled SAS3 (1.5 Gb/s, 3.0 Gb/s, 6.0 Gb/s, and 12.0 Gb/s) Compliance Software Option
QPHY-SATA-TSG-RSG
QualiPHY Enabled SATA (PHY, TSG, RSG, and OOB) Compliance Software Option
QPHY-SFI
QualiPHY Enabled SFI Compliance Software Option
QPHY-USB
QualiPHY Enabled USB 2.0 Compliance Software Option
QPHY-USB3.2-Tx-Rx
QualiPHY Enabled USB 3.2 Compliance Tx-Rx Software Option

Serial Data Analysis

WM8Zi-SDAIII-PAMx
PAMx Serial Data Analysis, Eye, Jitter and Noise Measurements for WaveMaster 8 Zi Series
SDA8Zi-CompleteLinQ
Bundle - Multi-Lane SDA LinQ Framewk, incl. Eye, Jitter, Noise, Xtalk Meas, w/EyeDrII & VirtualProbe
WM8Zi-EYEDRII
Signal Integrity Toolkit - Channel & Fixture De-embedding/Emulation, Tx/Rx Equalization
WM8Zi-EYEDRII-VP
Bundle - EyeDrII and VirtualProbe Toolkits
WM8Zi-VIRTUALPROBE
Advanced De-embedding, Emulation and Virtual Probing Toolkit

Other Software Options

MAUI Studio Pro
MAUI Studio Pro Offline Remote and PC Analysis Software License
WM8ZI-CROSSSYNC-PHY-PCIE
PCIe CrossSync PHY protocol analyzer synchronization for WaveMaster 8 Zi
WM8ZI-CROSSSYNC-PHY-USB
USB CrossSync PHY protocol analyzer synchronization for WaveMaster 8 Zi
WM8Zi-EMC
EMC Pulse Parameter Software Package for WaveMaster 8 Zi Series
WM8ZI-OPTICAL-LINQ
Coherent optical analysis software for WaveMaster 8Zi
WM8Zi-SPECTRUM-1
Spectrum Analyzer for WaveMaster 8 Zi - 1 trace
WM8Zi-SPECTRUM-PRO-2R
Spectrum Analyzer for WaveMaster/SDA/DDA 8 Zi - 2 traces + reference
WM8Zi-VECTORLINQ
VectorLinQ Vector Signal Analysis
WM8Zi-VECTORLINQ-ADV
VectorLinQ Advanced Vector Signal Analysis incl OFDM

Miscellaneous

WM8Zi-RACKMOUNT
Rack-mount accessory for converting a WaveMaster, SDA, and DDA 8 Zi series oscilloscope to an 8U rack-mounted package
OC1024-A
Instrument Cart with additional shelf and drawer

Data Storage Software

WM8Zi-AORM
Advanced Optical Recording Measurement Package for WaveMaster 8 Zi Series
WM8Zi-DDA
Disk Drive Analyzer Software Package for WaveMaster 8 Zi Series
WM8Zi-DDM2
Disk Drive Measurements Software Package for WaveMaster 8 Zi Series

Mixed Signal Accessories

MSO-DLS-18
16" Digital Lead Set, D0-D17
HDA-DLS-18QL
18 channel QuickLink leadset for HDA125
HDA-DLS-09QL
9 channel QuickLink leadset for HDA125

Serial Data Test Fixtures

TF-AUTO-ENET
Automotive Ethernet Breakout Test Fixture for 100Base-T1 and 1000Base-T1 Debug
TF-AUTO-ENET-SMA
4 pack of SMA Connector boards for TF-AUTO-ENET
TF-AUTO-HMTD
Test Fixture HMTD-Connector (m) to SMA (f)
TF-AUTO-MATENET
Test Fixture MATEnet-Connector (m) to SMA (f)
TF-AUTO-MINI50
Test Fixture Mini-50-Connector (m) to SMA (f)
TF-ENET-B
10/100/1000BaseT Ethernet Test Fixture
TF-HDMI-3.3V-QUADPAK
HDMI Pull-Up Terminator Quad Pack - For Use with the Wilder-Tech HDMI-TPA-P Plug Test Adapter
TF-MIPI-MPHY-DUALPAK
MIPI M-PHY input offset adapter dual pack
TF-NBASE-T
TF-NBASE-T supports both NBase-T and 10GBase-T compliance testing. It breaks out the A, B, C and D pairs from the Ethernet cable to SMA connectors. The kit includes power splitter (2) for adding the disturbing signal (for 2.5GBase-T), 50 Ohm terminators (6), Ethernet cables (2), SMA/SMA cables (2) and SMA/BNC cables (4) needed for testing.
TF-SATA-C-Kit
SATA Compliance Test Kit
TF-USB-B
USB 2.0 Compliance Test Fixture
TF-USB-C-HS
USB4 High-speed and Sideband Test Coupon Fixture
TF-USB-C-SB
USB4 Sideband Test Coupon Fixture
TF-USB3
SuperSpeed and SuperSpeedPlus USB Test Fixtures

Serial Trigger Hardware

WM8Zi-14GBIT-80B-SYMBOL-TD
80-bit NRZ, 8b/10b, and 64b/66b 14.1 Gbps Serial Trigger option for WaveMaster 8 Zi-A and DDA 8 Zi-A Limited Availability

Miscellaneous Accessories

MSO-DLS-36
16" Digital Lead Set, D18-D35

Differential Probes (4-6 GHz)

Dx10-SI
Replacement Solder tip lead set for D410/D610
Dx20-SI
Replacement Solder tip lead set for D420/D620
Dx10-PT-KIT
WaveLink Dx10-PT Adjustable Positioner Tip Kit. Includes XYZ Positioner Assembly with Mechanical Interconnects, Adhesive Kit, Connection Guides, Hand-held Wand, and Replacement Pins(Qty. 4)/Sockets (Qty 2).
Dx20-PT-KIT
WaveLink Dx20-PT Adjustable Positioner Tip Kit. Includes XYZ Positioner Assembly with Mechanical Interconnects, Adhesive Kit, Connection Guides, Hand-held Wand, and Replacement Pins (Qty. 4)/Sockets(Qty. 2).
Dx10-HiTemp
WaveLink Temperature Extension cables for Dx10. Includes 1 set of matched 30" high temperature cables, 1 solder tip lead set
Dx20-HiTemp
WaveLink Temperature Extension cables for Dx20. Includes 1 set of matched 30" high temperature cables, 1 solder tip lead set
Dx10-QL-3SI
QuickLink Solder-In starter pack for use with Dx10 amplifier
Dx20-QL-3SI
QuickLink Solder-In starter pack for use with Dx20 amplifier
D610-A-CCNIST
NIST Calibration for D610-A. Includes test data.
D620-A-CCNIST
NIST Calibration for D620-A. Includes test data.
D410-A-CCNIST
NIST Calibration for D410-A. Includes test data.
D420-A-CCNIST
NIST Calibration for D420-A. Includes test data.
D410-A-PB2
4 GHz ProBus2 Differential Probe with Dx10-SI Solder-In Tip (Qty. 1), Dx10-QC Quick Connect (Qty. 1) and Dx10-SP Square Pin (Qty. 1)
D420-A-PB2
4 GHz ProBus2 Differential Probe with Dx20-SI Solder-In Tip (Qty. 1), Dx20-QC Quick Connect (Qty. 1) and Dx20-SP Square Pin (Qty. 1)
D610-A-PL
6 GHz ProLink Differential Probe with Dx10-SI Solder-In Tip (Qty. 1), Dx10-QC Quick Connect (Qty. 1) and Dx10-SP Square Pin (Qty. 1)
D620-A-PL
6 GHz ProLink Differential Probe with Dx20-SI Solder-In Tip (Qty. 1), Dx20-QC Quick Connect (Qty. 1) and Dx20-SP Square Pin (Qty. 1)
D400A-AT-PB2
4 GHz ProBus2 Differential Probe with Adjustable Tip
D600A-AT-PL
6 GHz ProLink Differential Probe with Adjustable Tip
LPA-PBUS2
ProLink to ProBus2 Adapter

Active Voltage Probes

ZS1500
1.5 GHz, 0.9 pF, 1 MOhm Active Voltage Probe
ZS1000
1 GHz, 0.9 pF, 1 MOhm Active Voltage Probe
ZS2500
2.5 GHz, 0.9 pF, 1 MOhm Active Voltage Probe
ZS4000
4.0 GHz, 0.6 pF, 1 MOhm Active Voltage Probe

Differential Probes (<= 1.5 GHz)

AP033
500 MHz Differential Probe
ZD200
200 MHz, 3.5 pF, 1 MOhm Active Differential Probe, ±20 V Limited Availability
ZD500
500 MHz, 1.0 pF Active Differential Probe, ±8 V
ZD1000
1 GHz, 1.0 pF Active Differential Probe, ±8 V
ZD1500
1.5 GHz, 1.0 pF Active Differential Probe, ±8 V

Current Probes

CP150
150 A, 10 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 2 meter cable Limited Availability
CP500
500 A, 2 MHz Current Probe - AC/DC, 500 A rms, 700 A Peak Pulse, 6 meter cable
CP030
30A, 50 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable Limited Availability
CP031
30A, 100 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable
CP030A
30A, 50 MHz High Sensitivity Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable Limited Availability
CP031A
30A, 100 MHz High Sensitivity Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 1.5 meter cable
CA10
Programmable Current Sensor to ProBus Adapter for use with third party current sensors
CP030-3M
30 A, 10 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 3 meter cable Limited Availability
CP150-6M
150 A, 5 MHz Current Probe - AC/DC, 150 A rms, 500 A Peak Pulse, 6 meter cable Limited Availability
DCS025
Deskew Calibration Source for Teledyne LeCroy current probes

High Voltage Passive Probes

HVP120
6kV High Voltage Passive Probe, 400 MHz

Passive Probes

PP021-1
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP025-1
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm

High Voltage Differential Probes

AP031
700 V, 25 MHz High-Voltage Differential Probe (÷10, ÷100) Limited Availability
HVD3102A
1kV, 25 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3102A-NOACC
1kV, 25 MHz High Voltage Differential Probe without tip Accessories and with Auto Zero Disconnect
HVD3106A
1kV, 120 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3106A-NOACC
1kV, 120 MHz High Voltage Differential Probe without tip Accessories and with Auto Zero Disconnect
HVD3106A-6M
1kV, 80 MHz High Voltage Differential Probe with 6m cable and Auto Zero Disconnect
HVD3206A
2kV, 120 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3206A-6M
2kV, 80 MHz High Voltage Differential Probe with 6m cable and Auto Zero Disconnect
HVD3605A
6kV, 100 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3220
2kV, 400 MHz High Voltage Differential Probe

Transmission Line Probes

PP066
7.5 GHz low capacitance Passive Probe, 500/1K Ohms

Probe Parts and Kits

LPA-SMA-A
Pro-Link to SMA Adapter, new style
LPA-K-A
Pro-Link to K/2.92mm Adapter
Dx10-HiTEMP
WaveLink Temperature Extension cables for Dx10. Includes 1 set of matched 30" high temperature cables, 1 solder tip lead set
Dx20-HiTEMP
WaveLink Temperature Extension cables for Dx20. Includes 1 set of matched 30" high temperature cables, 1 solder tip lead set
Dx10-SI-HiTEMP
Replacement Solder tip leadset for use with D410/D610 and temperature extension cables
Dx20-SI-HiTEMP
Replacement Solder tip leadset for use with D420/620 and temperature extension cables
OE695G-REFCAL
OE695G Reference Cal (1ch)
Dx10-Cable-HiTemp
Replacement 30" matched cable set for use with Dx10 HiTemp Solder tip leadset
Dx20-Cable-HiTemp
Replacement 30" matched cable set for use with Dx20 HiTemp Solder tip leadset

Probe Adapters

LPA-2.92
ProLink to 2.92mm Adapter with Probe Power and Communication Pass Through
TPA10
TekProbe to ProBus Probe Adapter

Active Voltage Rail Probe

RP4030
Power/Voltage Rail Probe. 4 GHz bandwidth, 1.2x attenuation, +/-30V offset, +/-800mV Includes a complete set of solder-in leads, coaxial cables, and PCB mounts. Limited Availability
RP4000-MCX-LEAD-SI
Qty 3 MCX 4 GHz solder-in lead accessories (additional to those supplied with rail probe) 18cm long
RP4000-BROWSER
RP2060/RP4060 Browser Tip accessory. Includes 0 Ohm (1x), 450 Ohm (10x) and 950 Ohm (20x) tips.
RP4060
Power/Voltage Rail Probe. 4 GHz bandwidth, 1.2x attenuation, +/-60V offset, +/-800mV Includes a complete set of solder-in leads and coaxial cables. Browser tip sold seperately
RP2060
Power/Voltage Rail Probe. 2 GHz bandwidth, 1.2x attenuation, +/-60V offset, +/-800mV Includes a complete set of solder-in leads and coaxial cables. Browser tip sold seperately

High Voltage Optically Isolated Probes

HVFO100-1X-TIP-U
HVFO10X +/-1V (1x Attenuation) Universal Tip Accessory
HVFO100-5X-TIP-U
HVFO10X +/-5V (5x Attenuation) Universal Tip Accessory
HVFO100-10X-TIP-U
HVFO10X +/-10V (10x Attenuation) Universal Tip Accessory
HVFO100-20X-TIP-U
HVFO10X +/-20V (20x Attenuation) Universal Tip Accessory
HVFO100-40X-TIP-U
HVFO10X +/-40V (40x Attenuation) Universal Tip Accessory
HVFO108
High Voltage Fiber Optic Probe, 150 MHz Bandwidth. Includes soft-carrying case. Requires attenuating tip (ordered separately). Includes Qty. 1 1m Fiber Optic Cable.

Differential Probes (8-30 GHz)

DH13-PL
13 GHz differential probe with ProLink interface
DH16-PL
16 GHz differential probe with ProLink interface
DH20-PL
20 GHz differential probe with ProLink interface
DH-SI-HS
DH series high-sensitivity solder-in tip, 30 GHz BW, 2.0 Vpp range
DH-SI
DH series solder-in tip, 30 GHz BW, 3.5 Vpp range
DH-HITEMP
DH series high-temperature solder-in tip, 16 GHz BW, 3.5 Vpp range
DH-QL
DH series QuickLink adapter, 8 GHz BW
DH-QL-3SI
DH series QuickLink adapter kit with 3 x QL-SI tips
DH08-PL
8 GHz differential probe with ProLink interface
DH-PT
DH series PT browser tip, 16 GHz BW, 3.5 Vpp range

60 V Common Mode Differential Probes

DL05-HCM
500 MHz 60 V Common Mode Differential Probe. Includes standard set of leads and tips.
DL10-HCM
1 GHz 60 V Common Mode Differential Probe. Includes standard set of leads and tips.
DL-HCM-HiTemp
DL-HCM series high-temperature solder-in tip, 30 MHz bandwidth, 1 meter length.
DL-HCM-Acc-Kit
DL-HCM series accessories kit with probe holder, micro IC grabbers (Qty 2.), and Y-banana adaptor.
DL02-HCM
250 MHz 60 V Common Mode Differential Probe. Includes standard set of leads and tips.